HAZARD WARNING SWITCH INSPECTION


  1. INSPECT HAZARD WARNING SWITCH ASSEMBLY (for Manual Air Conditioning System)


    1. A01J3FNE02

      Measure the resistance of the switch.

      Standard resistance:
      Tester Connection Switch Condition Specified Condition
      2 (E) - 4 (TB) OFF 10 kΩ or higher
      2 (E) - 4 (TB) ON Below 1 Ω

      If the result is not as specified, replace the switch assembly.

    2. Check illumination operation.


      1. Connect the battery's positive (+) lead to terminal 8 and negative (-) lead to terminal 9. Then check that the bulb illuminates.

        OK
        Bulb illuminates.

        If the result is not as specified, replace the switch assembly.