INSPECT PRESSURE SWITCH (for Dual A/C)
Magnetic clutch control: Inspect the pressure switch operation.
Set on the manifold gauge set.
Connect the positive (+) lead from the ohmmeter to terminal 2 and the negative (-) lead to terminal 1.
Check the continuity between terminals when refrigerant pressure is charge, as shown in the illustration.
If operation is not as specified, replace the pressure switch.
Cooling fan control: Inspect the pressure switch operation.
Connect the positive (+) lead from the ohmmeter to terminal 4 and the negative (-) lead to terminal 3.
Check the continuity between terminals when refrigerant pressure is charged, as shown in the illustration.
If operation is not as specified, replace the pressure switch.
Check PRESSURE SWITCH (for Single A/C)
Set on the manifold gauge set.
Connect the positive (+) lead from the ohmmeter to terminal 1 and the negative (-) lead to terminal 2.
Check the continuity between terminals when refrigerant pressure is charged, as shown in the illustration.
If operation is not as specified, replace the pressure switch.