ROOM TEMPERATURE SENSOR (for Automatic Air Conditioning System) INSPECTION


  1. INSPECT COOLER THERMISTOR


    1. Remove the cooler thermistor.

    2. A01J3XVE02

      Measure the resistance of the thermistor.

      Tester Connection Condition Specified Condition
      1 - 2 10°C (50°F) 3.00 to 3.73 kΩ
      1 - 2 15°C (59°F) 2.45 to 2.88 kΩ
      1 - 2 20°C (68°F) 1.95 to 2.30 kΩ
      1 - 2 25°C (77°F) 1.60 to 1.80 kΩ
      1 - 2 30°C (86°F) 1.28 to 1.47 kΩ
      1 - 2 35°C (95°F) 1.00 to 1.22 kΩ
      1 - 2 40°C (104°F) 0.80 to 1.00 kΩ
      1 - 2 45°C (113°F) 0.65 to 0.85 kΩ
      1 - 2 50°C (122°F) 0.50 to 0.70 kΩ
      1 - 2 55°C (131°F) 0.44 to 0.60 kΩ
      1 - 2 60°C (140°F) 0.36 to 0.50 kΩ

      Note


      • Even slightly touching the thermistor may change the resistance value. Be sure to hold the connector of the thermistor.

      • When measuring the resistance, the thermistor temperature must be the same as the ambient temperature.

      Tech Tips

      As the temperature increases, the resistance decreases (see graph).