BLOWER UNIT DISASSEMBLY


  1. REMOVE AIR INLET DAMPER CONTROL CABLE SUB-ASSEMBLY (for Manual Air Conditioning System)

    A01J3TO

    1. Detach the 3 claws and remove the air inlet damper control cable sub-assembly.

  2. REMOVE RECIRCULATION DAMPER SERVO SUB-ASSEMBLY (for Automatic Air Conditioning System)


    1. A01J5WGE01
      Text in Illustration
      *1 Lever

      Detach the claw and remove the lever.

    2. A01J6E3

      Remove the 3 screws and recirculation damper servo sub-assembly.

  3. REMOVE CLEAN AIR FILTER

    A01J4RW

    1. Detach the claw and remove the air filter case.

    2. Remove the clean air filter.

  4. REMOVE BLOWER RESISTOR (for Manual Air Conditioning System)

    A01J7DC

    1. Remove the 2 screws and blower resistor.

  5. REMOVE BLOWER MOTOR CONTROL (for Automatic Air Conditioning System)

    A01J7LN

    1. Remove the 2 screws and blower motor control.

  6. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY

    A01J61L

    1. Remove the 3 screws and blower motor with fan sub-assembly.