AIR CONDITIONING SYSTEM (for Manual Air Conditioning System) PRECAUTION


  1. DO NOT HANDLE REFRIGERANT IN AN ENCLOSED AREA OR NEAR AN OPEN FLAME

    A01J4OC
  2. ALWAYS WEAR PROTECTIVE GLASSES

  3. AVOID SKIN OR EYE CONTACT WITH LIQUID REFRIGERANT

    A01J4D0

    If liquid refrigerant comes in contact with your eyes or skin:


    1. Rinse the area thoroughly with cold water.

      CAUTION:

      Do not rub your eyes or skin.

    2. Apply clean petroleum jelly to the skin.

    3. Go immediately to a hospital or see a physician for professional treatment.

  4. NEVER HEAT CONTAINER OR EXPOSE IT TO OPEN FLAME

  5. DO NOT DROP OR STRIKE CONTAINER OF REFRIGERANT

  6. DO NOT OPERATE COMPRESSOR WITHOUT ENOUGH REFRIGERANT IN REFRIGERANT SYSTEM

    A01J7M0E05

    If there is not enough refrigerant in the refrigerant system, oil lubrication will be insufficient and the compressor may burn out. Care should be taken to avoid this.

  7. DO NOT OPEN HIGH PRESSURE MANIFOLD VALVE WHILE COMPRESSOR IS OPERATING

    Open and close only the low pressure valve. If the high pressure valve is opened, refrigerant flows in the reverse direction and causes the charging cylinder to rupture.

  8. BE CAREFUL NOT TO OVERCHARGE SYSTEM WITH REFRIGERANT

    Overcharged refrigerant will cause problems such as insufficient cooling, poor fuel economy, engine overheating, etc.

  9. DO NOT OPERATE ENGINE AND COMPRESSOR WITHOUT REFRIGERANT IN REFRIGERANT SYSTEM

    Note

    This may damage the inside of the compressor because the compressor parts move regardless of whether the A/C system is turned on or off.