INSTALL TRANSMISSION WIRE
Install a new O-ring to the transmission wire.
Install the transmission wire with the bolt.
Connect the transmission wire connector.
CONNECT TRANSMISSION WIRE
Connect the 7 connectors to the solenoid valves.
Install the clamp with the 2 bolts.
Tech Tips
Each bolt length is indicated below.
| Bolt length |
|---|
| 36 mm (1.42 in.) for bolt A |
| 12 mm (0.47 in.) for bolt B |
Connect the ATF temperature sensor.
INSTALL VALVE BODY OIL STRAINER ASSEMBLY
Install a new O-ring and oil strainer with the 4 bolts.
INSTALL AUTOMATIC TRANSMISSION OIL PAN SUB-ASSEMBLY
Tech Tips
Remove the gasket and be careful not to spill oil on the contacting surfaces of the transmission case and oil pan.
Install the oil pan with the 20 bolts.
CONNECT CABLE TO NEGATIVE BATTERY TERMINAL
PERFORM INITIALIZATION
Perform initialization Click here.
Note
Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.
ADD AUTOMATIC TRANSMISSION FLUID
Add automatic transmission fluid Click here.
INSPECT AUTOMATIC TRANSMISSION FLUID
Inspect the automatic transmission fluid Click here.