PARK / NEUTRAL POSITION SWITCH INSPECTION


  1. INSPECT PARK/NEUTRAL POSITION SWITCH

    A01J46JE06

    1. Measure the resistance of the park/neutral switch when the shift lever is moved to each position

      Standard resistance
      Tester Connection Shift Lever Position Specified Condition
      4 (B) - 5 (L) P or N Below 1 Ω
      4 (B) - 5 (L) Not on P or N 10 kΩ or higher
      1 (RL) - 2 (RB) R Below 1 Ω
      1 (RL) - 2 (RB) Not on R 10 kΩ or higher
      2 (RB) - 7 (DL) D Below 1 Ω
      2 (RB) - 7 (DL) Not on D 10 kΩ or higher
      2 (RB) - 3 (2L) 2 Below 1 Ω
      2 (RB) - 3 (2L) Not on 2 10 kΩ or higher
      2 (RB) - 8 (LL) L Below 1 Ω
      2 (RB) - 8 (LL) Not on L 10 kΩ or higher