VACUUM SWITCHING VALVE INSPECTION


  1. INSPECT PURGE VSV


    1. A01J3VHE02

      Measure the resistance of the purge VSV.

      Standard resistance
      Tester Connection Specified Condition
      1 - 2 26 to 30 Ω at 20°C (68°F)

      1 - Body ground

      2 - Body ground

      10 MΩ or higher

      If the result is not as specified, replace the purge VSV.

    2. A01J5OME04

      Check operation of the purge VSV.


      1. Check that air does not flow from port E to port F.

      2. A01J7B1E01

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the purge VSV.