VACUUM SWITCHING VALVE INSPECTION


  1. INSPECT PURGE VSV


    1. A01J3VHE02

      Measure the resistance of the purge VSV.

      Standard resistance
      Tester Connection Specified Condition
      1 - 2 26 to 30 Ω at 20°C (68°F)
      1 - Body Ground 10 MΩ or higher
      2 - Body Ground

      If the result is not as specified, replace the purge VSV.

    2. A01J496E03

      Check the operation of the purge VSV.


      1. Check that air does not flow from port E to port F.

      2. A01J6VNE07

        Apply battery voltage across terminals 1 and 2.

      3. Check that air flows from port E to port F.

        If the result is not as specified, replace the purge VSV.