SFI SYSTEM (w/o Secondary Air Injection System) ECM Power Source Circuit

DESCRIPTION

When the ignition switch is turned ON, the battery voltage is applied to terminal IGSW of the ECM. The ECM "MREL" output signal causes a current to flow to the MAIN relay coil, closing the contacts of the MAIN relay and supplying power to terminal +B of the ECM.

WIRING DIAGRAM

A01J6XIE01

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK ECM (+B VOLTAGE)

    A01J4U2E97

    1. Turn the ignition switch ON.

    2. Measure the voltage of the ECM connectors.

      Standard voltage
      Tester Connection Specified Condition
      E8-1 (+B) - E11-3 (E1) 9 to 14 V

    OK
    NG
  2. CHECK WIRE HARNESS (ECM - BODY GROUND)

    A01J4R7E15

    1. Disconnect the E11 ECM connector.

    2. Measure the resistance of the wire harness side connector.

      Standard resistance
      Tester Connection Specified Condition
      E11-3 (E1) - Body ground Below 1 Ω

    NG
    OK
  3. CHECK ECM (IGSW VOLTAGE)

    A01J4U2E98

    1. Turn the ignition switch ON.

    2. Measure the voltage of the ECM connectors.

      Standard voltage
      Tester Connection Specified Condition
      E8-9 (IGSW) - E11-3 (E1) 9 to 14 V

    OK
    NG
  4. INSPECT FUSE (IGN)

    A01J47BE01

    1. Remove the IGN fuse from the instrument panel junction block.

    2. Measure the resistance of the fuse.

      Standard
      Below 1 Ω

    NG
    OK
  5. INSPECT IGNITION SWITCH ASSEMBLY

    A01J7H4E02

    1. Disconnect the I8 ignition switch connector.

    2. Measure the resistance of the switch.

      Standard resistance
      Tester Connection Switch Condition Specified Condition
      5 (AM2) - 6 (IG2) LOCK 10 kΩ or higher
      5 (AM2) - 6 (IG2) ON Below 1 Ω

    NG
    OK
  6. CHECK ECM (MREL VOLTAGE)

    A01J4U2E99

    1. Turn the ignition switch ON.

    2. Measure the voltage of the ECM connectors.

      Standard voltage
      Tester Connection Specified Condition
      E8-8 (MREL) - E11-3 (E1) 9 to 14 V

    NG
    OK
  7. INSPECT FUSE (EFI)

    A01J64OE05

    1. Remove the EFI fuse from the engine room junction block.

    2. Measure the resistance of the fuse.

      Standard resistance
      Below 1 Ω

    NG
    OK
  8. CHECK INTEGRATION NO.1 RELAY (MAIN RELAY)

    A01J6CYE16

    1. Remove the integration relay from the engine room junction block.

    2. Measure the voltage of the MAIN relay.

      Standard voltage
      Tester Connection Condition Specified Condition
      1J-4 - Body ground Ignition switch ON 10 to 14 V

    NG
    OK
  9. CHECK WIRE HARNESS (INTEGRATION RELAY (MAIN RELAY) - ECM, BODY GROUND)

    A01J3J9E03

    1. Remove the integration relay from the engine room junction block.

    2. Disconnect the 1J integration relay connector.

    3. Disconnect the E8 ECM connector.

    4. Measure the resistance of the wire harness side connectors.

      Standard resistance
      Tester Connection Specified Condition
      1J-2 - E8-8 (MREL) Below 1 Ω
      1J-4 - E8-1 (+B) Below 1 Ω
      1J-3 - Body ground Below 1 Ω
      1J-2 or E8-8 (MREL) - Body ground 10 kΩ or higher
      1J-4 or E8-1 (+B) - Body ground 10 kΩ or higher

    NG
    OK