CRANKSHAFT POSITION SENSOR INSTALLATION


  1. INSTALL CRANKSHAFT POSITION SENSOR


    1. A01J3WHE01

      Apply a light coat of engine oil to the O-ring of the sensor.

    2. Install the sensor with the bolt.

      Torque:
      9.0 N*m  { 92 kgf*cm, 80 in.*lbf }
    3. Connect the sensor connector.

  2. INSTALL COOLER COMPRESSOR ASSEMBLY (w/ Air Conditioning System)


    1. A01J6LEE01

      Temporarily install the compressor with the bolt labeled A.

    2. Install the compressor completely by tightening the 4 bolts in the order shown in the illustration.

      Torque:
      25 N*m  { 255 kgf*cm, 18 ft.*lbf }

      Note

      In order to prevent misalignment, which causes belt rattle, tightening of the bolts must be performed in the order shown.

    3. Connect the compressor connector.

    4. A01J5Y5

      Connect the suction hose with the 2 bolts.

      Torque:
      5.4 N*m  { 55 kgf*cm, 48 in.*lbf }
  3. INSTALL GENERATOR ASSEMBLY (w/ Air Conditioning System)

    A01J5AE

    1. Install the generator and adjusting bar with the 2 bolts.

      Torque:
      43 N*m  { 438 kgf*cm, 32 ft.*lbf }
    2. Install the generator wire with the nut.

      Torque:
      9.8 N*m  { 100 kgf*cm, 87 in.*lbf }
    3. Install the terminal cap.

    4. Connect the generator connector.

  4. INSTALL IDLER PULLEY (w/o Air Conditioning System)


    1. A01J4ZE

      Install the idler pulley with the 3 bolts.

      Torque:
      25 N*m  { 255 kgf*cm, 18 ft.*lbf }
  5. INSTALL DRIVE BELT


    1. A01J3ZEE02

      Temporarily install the V-ribbed belt tensioner with the 5 bolts.

    2. Install the V-ribbed belt tensioner by tightening bolt 1 and then bolt 2.

      Torque:
      36 N*m  { 367 kgf*cm, 27 ft.*lbf }
    3. Tighten the other bolts.

      Torque:
      36 N*m  { 367 kgf*cm, 27 ft.*lbf }

      Tech Tips

      Each bolt length is as follows:

      A = 70 mm (2.76 in.)

      B = 33 mm (1.30 in.)

  6. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

  7. PERFORM INITIALIZATION


    1. Perform initialization Click here.

      Note

      Certain systems need to be initialized after disconnecting and reconnecting the cable from the negative (-) battery terminal.