2TR-FE EMISSION CONTROL SERVICE DATA

AIR PUMP (w/ Secondary Air Injection System)
Condition Specified Condition
20°C (68°F) 10 to 40 A
AIR SWITCHING VALVE (w/ Secondary Air Injection System)
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 4.5 to 5.5 Ω
1 - Body ground Always 1 MΩ or higher
2 - Body ground
PURGE VALVE
Tester Connection Condition Specified Condition
1 - 2 20°C (68°F) 26 to 30 Ω
1 - Body ground Always 10 MΩ or higher
2 - Body ground
AIR FUEL RATIO SENSOR (w/ Secondary Air Injection System)
Tester Connection Condition Specified Condition
1 (HA1A) - 2 (+B) 20°C (68°F) 1.8 to 3.4 Ω
1 (HA1A) - 4 (A1A-) Always 10 KΩ or higher
HEATED OXYGEN SENSOR (w/ Secondary Air Injection System)
Tester Connection Condition Specified Condition
1 (HT1B) - 2 (+B) 20°C (68°F) 5 to 10 Ω
1 (HT1B) - 4 (E2) Always 10 KΩ or higher
HEATED OXYGEN SENSOR (w/o Secondary Air Injection System)
Tester Connection Condition Specified Condition
1 (HT1A) - 2 (+B) 20°C (68°F) 5 to 10 Ω