2TR-FE EMISSION CONTROL SERVICE DATA
AIR PUMP (w/ Secondary Air Injection System)
| Condition |
Specified Condition |
| 20°C (68°F) |
10 to 40 A |
AIR SWITCHING VALVE (w/ Secondary Air Injection System)
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
4.5 to 5.5 Ω |
| 1 - Body ground |
Always |
1 MΩ or higher |
| 2 - Body ground |
PURGE VALVE
| Tester Connection |
Condition |
Specified Condition |
| 1 - 2 |
20°C (68°F) |
26 to 30 Ω |
| 1 - Body ground |
Always |
10 MΩ or higher |
| 2 - Body ground |
AIR FUEL RATIO SENSOR (w/ Secondary Air Injection System)
| Tester Connection |
Condition |
Specified Condition |
| 1 (HA1A) - 2 (+B) |
20°C (68°F) |
1.8 to 3.4 Ω |
| 1 (HA1A) - 4 (A1A-) |
Always |
10 KΩ or higher |
HEATED OXYGEN SENSOR (w/ Secondary Air Injection System)
| Tester Connection |
Condition |
Specified Condition |
| 1 (HT1B) - 2 (+B) |
20°C (68°F) |
5 to 10 Ω |
| 1 (HT1B) - 4 (E2) |
Always |
10 KΩ or higher |
HEATED OXYGEN SENSOR (w/o Secondary Air Injection System)
| Tester Connection |
Condition |
Specified Condition |
| 1 (HT1A) - 2 (+B) |
20°C (68°F) |
5 to 10 Ω |