COOLER EXPANSION VALVE REMOVAL

PROCEDURE


  1. RECOVER REFRIGERANT FROM REFRIGERATION SYSTEM

    Click here

  2. DISCONNECT SUCTION TUBE SUB-ASSEMBLY B

    Click here

  3. DISCONNECT LIQUID TUBE SUB-ASSEMBLY A

    Click here

  4. REMOVE COOLER EXPANSION VALVE


    1. A01UZ9D

      Using a 4 mm hexagon wrench, remove the 2 hexagon bolts.

    2. A01V11PE01
      Text in Illustration
      *1 Bolt For The Suction Tube Sub-assembly

      Temporarily attach the bolt for the suction tube sub-assembly halfway to the cooler expansion valve.

    3. A01UXHS

      Hold the bolt and pull it to remove the cooler expansion valve as shown in the illustration.

    4. A01V1XQE01
      Text in Illustration
      *1 Cooler Evaporator

      Remove the 2 O-rings from the cooler evaporator.