BLOWER UNIT REASSEMBLY

PROCEDURE


  1. INSTALL CLEAN AIR FILTER


    1. A01UYJG

      Install the clean air filter into the blower.

      Note

      Install the clean air filter with its UP mark oriented in the correct direction.

  2. INSTALL AIR FILTER CASE


    1. A01V0Q9E01

      Insert the rib of the air filter case into the blower unit.

      Note

      Install the air filter case with its UP mark oriented in the correct direction.

    2. Pinch portion A to engage the claw and install the air filter case.

  3. INSTALL BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. A01UY5Y

      Install the blower motor with the 3 screws.

  4. INSTALL NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY


    1. A01UXZ6

      Install the blower damper servo with the 2 screws.

  5. INSTALL NO. 4 HEATER TO REGISTER DUCT (w/ Glove Box Light)


    1. A01UYWB

      Engage the 2 guides and install the heater to register duct.

    2. Tighten the 2 screws.

  6. INSTALL NO. 1 AIR DUCT SUB-ASSEMBLY


    1. A01UYSY

      Engage the 2 claws and 2 guides, and install the air duct.