BLOWER UNIT DISASSEMBLY

PROCEDURE


  1. REMOVE NO. 1 AIR DUCT SUB-ASSEMBLY


    1. A01UYSY

      Disengage the 2 claws and 2 guides, and remove the air duct.

  2. REMOVE NO. 4 HEATER TO REGISTER DUCT (w/ Glove Box Light)


    1. A01UYWB

      Remove the 2 screws.

    2. Disengage the 2 guides and remove the heater to register duct.

  3. REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY


    1. A01UXZ6

      Remove the 2 screws and the blower damper servo.

  4. REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY


    1. A01UY5Y

      Remove the 3 screws and the blower motor.

  5. REMOVE AIR FILTER CASE


    1. A01UXVNE01

      Pinch portion A to disengage the claw and remove the air filter case.

  6. REMOVE CLEAN AIR FILTER


    1. A01V16T

      Remove the clean air filter from the blower.