PROCEDURE
REMOVE NO. 1 AIR DUCT SUB-ASSEMBLY
Disengage the 2 claws and 2 guides, and remove the air duct.
REMOVE NO. 4 HEATER TO REGISTER DUCT (w/ Glove Box Light)
Remove the 2 screws.
Disengage the 2 guides and remove the heater to register duct.
REMOVE NO. 1 BLOWER DAMPER SERVO SUB-ASSEMBLY
Remove the 2 screws and the blower damper servo.
REMOVE BLOWER MOTOR WITH FAN SUB-ASSEMBLY
Remove the 3 screws and the blower motor.
REMOVE AIR FILTER CASE
Pinch portion A to disengage the claw and remove the air filter case.
REMOVE CLEAN AIR FILTER
Remove the clean air filter from the blower.