DESCRIPTION
The main power source supplied to the air conditioning amplifier assembly when the ignition switch is turned to ON (IG). The power source is used for operating the air conditioning amplifier assembly, servo motors, etc.
WIRING DIAGRAM
| *a | from IG1 NO. 1 Relay |
| *b | A/C |
| *c | Air Conditioning Amplifier Assembly |
CAUTION / NOTICE / HINT
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
CHECK HARNESS AND CONNECTOR (AIR CONDITIONING AMPLIFIER ASSEMBLY - IG1 NO. 1 RELAY AND BODY GROUND)
| *a | Front view of wire harness connector (to Air Conditioning Amplifier Assembly) |
Disconnect the air conditioning amplifier assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||||
|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here |
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |