AIR CONDITIONING SYSTEM, Diagnostic DTC:B1411/11

DTC Code DTC Name
B1411/11 Room Temperature Sensor Circuit

DESCRIPTION

The cooler thermistor (room temperature sensor) for the front seat is installed in the instrument panel to detect the room temperature and control the heater and air conditioner auto mode. The resistance of the room temperature sensor changes in accordance with the front room temperature. As the temperature decreases, the resistance increases. As the temperature increases, the resistance decreases.

The air conditioning amplifier assembly applies voltage (5 V) to the room temperature sensor and reads voltage changes as the resistance of the room temperature sensor changes. This sensor also sends the appropriate signals to the air conditioning amplifier assembly.

DTC No. DTC Detection Condition Trouble Area
B1411/11 An open or short in the cooler thermistor (room temperature sensor) circuit.
  • Cooler thermistor (room temperature sensor)

  • Harness or connector between cooler thermistor (room temperature sensor) and air conditioning amplifier assembly

  • Air conditioning amplifier assembly

WIRING DIAGRAM

A01UXUUE01
*a Cooler Thermistor (Room Temperature Sensor)
*b Air Conditioning Amplifier Assembly

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Air Conditioner / Data List.

    5. According to the display on the GTS, read the Data List.

      Air Conditioner
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      Room Temperature Sensor

      Room temperature sensor /

      Min.: -6.5°C (20.3°F)

      Max.: 57.25°C (135.1°F)

      Actual room temperature is displayed -
      OK
      The display is as specified in the normal condition column.
      Result
      Result Proceed to
      OK (When troubleshooting according to the DTC) A
      OK (When troubleshooting according to Problem Symptoms Table) B
      NG C

    B
    C
    A
  2. CHECK FOR DTC


    1. Clear the DTCs Click here.

    2. Check for DTCs Click here.

      OK
      DTC B1411/11 is not output

    OK
    NG
  3. INSPECT COOLER THERMISTOR (ROOM TEMPERATURE SENSOR)


    1. Inspect the cooler thermistor (room temperature sensor) Click here.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (COOLER THERMISTOR (ROOM TEMPERATURE SENSOR) - AIR CONDITIONING AMPLIFIER ASSEMBLY)


    1. Disconnect the F25 cooler thermistor (room temperature sensor) connector.

    2. Disconnect the F29 air conditioning amplifier assembly connector.

    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F25-1 (+) - F29-29 (TR) Always Below 1 Ω
      F25-2 (-) - F29-34 (SG-1) Always Below 1 Ω
      F25-1 (+) - Body ground Always 10 kΩ or higher
      F25-2 (-) - Body ground Always 10 kΩ or higher

    OK