LIGHTING SYSTEM IG Signal Circuit

DESCRIPTION

This circuit detects the ignition switch ON (IG) or off condition, and sends it to the main body ECU.

WIRING DIAGRAM

A01V0JHE05

CAUTION / NOTICE / HINT

Note

Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. According to the display on the GTS, read the Data List.

      Main Body
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      IG SW

      Ignition switch ON (IG) signal /

      OFF or ON

      OFF: Ignition switch ACC or off

      ON: Ignition switch ON (IG)

      -
      OK
      Normal conditions listed above are displayed.

    OK
    NG
  2. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - AUXILIARY BATTERY AND BODY GROUND)

    A01UXHLE03
    Text in Illustration
    *a

    Front view of wire harness connector

    (to Instrument Panel Junction Block Assembly)


    1. Disconnect the instrument panel junction block assembly connectors.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      3E-1 - Body ground Always 11 to 14 V
    3. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3B-8 - Body ground Always Below 1 Ω

    NG
    OK
  3. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - POWER MANAGEMENT CONTROL ECU OR IGNITION SWITCH)

    A01UZ61E08
    Text in Illustration
    *a

    Component with harness connected

    (Instrument Panel Junction Block Assembly)


    1. Reconnect the instrument panel junction block assembly connectors.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      3A-29 - Body ground Ignition switch ON (IG) 11 to 14 V

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)


    1. Disconnect the 3A instrument panel junction block assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      3A-40 - 3A-54 Always Below 1 Ω
      3A-40 - Body ground Always 10 kΩ or higher

    NG
    OK
  5. REPLACE MAIN BODY ECU


    1. Replace the main body ECU Click here.


    NEXT
  6. READ VALUE USING GTS


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON (IG).

    3. Turn the GTS on.

    4. Enter the following menus: Body Electrical / Main Body / Data List.

    5. According to the display on the GTS, read the Data List.

      Main Body
      Tester Display Measurement Item/Range Normal Condition Diagnostic Note
      IG SW

      Ignition switch ON (IG) signal /

      OFF or ON

      OFF: Ignition switch ACC or off

      ON: Ignition switch ON (IG)

      -
      OK
      Normal conditions listed above are displayed.

    OK
    NG