LANE DEPARTURE ALERT SYSTEM FAIL-SAFE CHART


  1. FAIL-SAFE FUNCTION


    1. When the pre-crash safety city sensor detects high temperatures, the LDA indicator in the combination meter assembly illuminates and the system enters a temporary controlled stop (for Segment Display Type).

      When the temperature of the pre-crash safety city sensor is excessively high, operation of the lane departure alert system is temporarily suspended and "LDA not available" is displayed on the multi-information display in the combination meter assembly (for TFT Display Type).

      Temporary Stop Conditions Recovery Conditions
      High front camera temperature detected Pre-crash safety city sensor returns to operational temperature

      Tech Tips

      When high front camera temperatures are detected, a pre-crash safety system malfunction is also displayed.

    2. A004ENHE02
      Text in Illustration
      *a LDA Indicator (Yellow)

      for Segment Display Type

      When a system malfunction is detected, the LDA indicator (yellow) is displayed in the combination meter assembly together with a "pong" sound.

    3. for TFT Display Type

      When a system malfunction is detected, the MIL illuminates, "Check LDA system" is displayed on the multi-information display in the combination meter assembly and the buzzer sounds.

      Stop Conditions Recovery Conditions
      Lane departure alert system malfunction detected Lane departure alert system DTCs not detected

      Tech Tips

      For details on checking the DTCs Click here.