POWER SWITCH INSPECTION

PROCEDURE


  1. INSPECT POWER SWITCH


    1. Measure the resistance according to the value(s) in the table below.

      A01V0VNE03
      Standard Resistance
      Tester Connection Switch Condition Specified Condition
      5 (SS1) - 6 (AGND) Pushed Below 1 Ω
      1 (SS2) - 6 (AGND) Pushed Below 1 Ω
      5 (SS1) - 6 (AGND) Not pushed 10 kΩ or higher
      1 (SS2) - 6 (AGND) Not pushed 10 kΩ or higher

      If the result is not as specified, replace the power switch.

    2. Apply battery voltage between the terminals of the switch, and check the illumination condition of the power switch.

      A01V0VNE04
      Text in Illustration
      *a Power Switch Illumination - -
      Standard Resistance
      Measurement Condition Specified Condition

      Auxiliary battery positive (+) →Terminal 9 (SWIL)

      Auxiliary battery negative (-) →Terminal 6 (AGND)

      Illuminates

      (Power Switch Illumination)

      If the result is not as specified, replace the power switch.