CANISTER INSPECTION

PROCEDURE


  1. CHECK CHARCOAL CANISTER


    1. Inspect the ventilation of the canister.


      1. A01V0JVE02
        Text in Illustration
        *a Air

        Apply compressed air into port A and check that air flows out from port B.

        If a problem is found, replace the fuel suction plate sub-assembly.

    2. Inspect the check valve.


      1. A01V0LKE02
        Text in Illustration
        *a Air

        Close port A and apply compressed air into port B.

        OK
        Air does not flow at first. By gradually increasing the pressure, air flows when the pressure in the port reaches the specified level.
      2. A01V0UYE02

        Close port A. Using a hand-held vacuum pump, apply a vacuum to port B.

        OK
        The vacuum is maintained at first. By gradually increasing the vacuum, air flows and the vacuum decreases after the vacuum reaches the specified level.