WATER PUMP WITH MOTOR INSTALLATION

PROCEDURE


  1. INSTALL HV WATER PUMP BRACKET SUB-ASSEMBLY


    1. Install the HV water pump bracket sub-assembly with the 2 bolts.

      Torque:
      20 N*m  { 199 kgf*cm, 14 ft.*lbf }
    2. Connect the clamp.

  2. INSTALL INVERTER WATER PUMP ASSEMBLY


    1. Install the inverter water pump assembly with the 3 bolts.

      Torque:
      6.1 N*m  { 62 kgf*cm, 54 in.*lbf }

      Note

      Do not hold the inverter water pump assembly by the connector terminals when removing or installing it.

    2. Connect the connector.

    3. A01UZIME02
      Text in Illustration
      *1 Clamp A
      *2 Clamp B
      *a Alignment Mark (White)
      *b Alignment Mark (Yellow)
      *c Rib
      *d 90°
      *e 45°

      Connect the 2 HV water pump hoses.

      Note


      • Connect the HV water pump hoses securely up to the rib of the inverter water pump assembly.

      • Make sure to align the alignment marks of the hoses with the ribs of the inverter water pump assembly.

      • Do not remove the pieces of cloth from the pipes and disconnected hoses until installation to prevent foreign matter from entering the inverter water pump and cooling system.

      • Make sure that the clamp A is positioned as shown in the illustration.

      Tech Tips

      Clamp B can be oriented in any angle.

  3. INSTALL INVERTER BRACKET ASSEMBLY

    Click here

  4. INSTALL INVERTER WITH CONVERTER ASSEMBLY

    Click here.