PROCEDURE
INSTALL HV WATER PUMP BRACKET SUB-ASSEMBLY
Install the HV water pump bracket sub-assembly with the 2 bolts.
Connect the clamp.
INSTALL INVERTER WATER PUMP ASSEMBLY
Install the inverter water pump assembly with the 3 bolts.
Note
Do not hold the inverter water pump assembly by the connector terminals when removing or installing it.
Connect the connector.
| *1 | Clamp A |
| *2 | Clamp B |
| *a | Alignment Mark (White) |
| *b | Alignment Mark (Yellow) |
| *c | Rib |
| *d | 90° |
| *e | 45° |
Connect the 2 HV water pump hoses.
Note
Connect the HV water pump hoses securely up to the rib of the inverter water pump assembly.
Make sure to align the alignment marks of the hoses with the ribs of the inverter water pump assembly.
Do not remove the pieces of cloth from the pipes and disconnected hoses until installation to prevent foreign matter from entering the inverter water pump and cooling system.
Make sure that the clamp A is positioned as shown in the illustration.
Tech Tips
Clamp B can be oriented in any angle.
INSTALL INVERTER BRACKET ASSEMBLY
INSTALL INVERTER WITH CONVERTER ASSEMBLY