PROCEDURE
PRECAUTION
REMOVE FRONT FLOOR COVER RH (for Front Floor Cover Type A)
REMOVE FRONT FLOOR COVER LH (for Front Floor Cover Type A)
REMOVE CENTER FRONT FLOOR COVER (for Front Floor Cover Type A)
REMOVE CENTER FRONT FLOOR COVER (for Front Floor Cover Type B)
REMOVE FRONT FLOOR COVER RH (for Front Floor Cover Type B)
DISCONNECT CABLE FROM NEGATIVE AUXILIARY BATTERY TERMINAL
REMOVE SERVICE PLUG GRIP
DRAIN COOLANT (for Inverter)
REMOVE HOOD STAY HOLDER
Disengage the claw and remove the hood stay holder.
REMOVE INVERTER TERMINAL COVER
CAUTION:
Wear insulated gloves.
| *1 | Interlock Connector |
Remove the 2 bolts and inverter terminal cover.
CAUTION:
An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.
Note
Make sure to pull the inverter terminal cover straight up to remove it, because an interlock connector is connected to the bottom of the inverter terminal cover.
REMOVE INVERTER COVER
CAUTION:
Wear insulated gloves.
Remove the 7 bolts and inverter cover.
CAUTION:
An interlock connector is installed to the inverter terminal cover. Make sure to remove the inverter terminal cover before removing the inverter cover.
CHECK TERMINAL VOLTAGE
CAUTION:
Wear insulated gloves.
Note
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Using a voltmeter, measure the voltage between the terminals of the 2 phase connectors.
| Standard voltage |
|---|
| 0 V |
Tech Tips
Use measuring range of DC 750 V or more on the voltmeter.
DISCONNECT ENGINE ROOM MAIN WIRE
CAUTION:
Wear insulated gloves.
Note
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Raise the lock lever and disconnect the inverter with converter connector.
Disconnect the engine wire from the engine room main wire.
| *1 | Hybrid Water Pump Inlet Hose |
Disengage the clamp and disconnect the hybrid water pump inlet hose from the engine room main wire.
Note
Do not remove the hose clamp from the hybrid water pump inlet hose.
Remove the 2 bolts.
Disengage the clamp and disconnect the engine room main wire.
DISCONNECT FRAME WIRE
CAUTION:
Wear insulated gloves.
Note
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
Disconnect the harness clamp.
Remove the 4 bolts, and disconnect the frame wire (high voltage cables of the hybrid battery) from the inverter with converter assembly.
DISCONNECT MOTOR CABLE
CAUTION:
Wear insulated gloves.
Note
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
Disconnect the motor cable (for MG 1)
Remove the 5 bolts, and disconnect the high voltage cables of the motor cable for (MG1) from the inverter with converter assembly.
Disconnect the motor cable (for MG 2)
Remove the 5 bolts, and disconnect the high voltage cables of the motor cable (for MG2) from the inverter with converter assembly.
DISCONNECT NO. 2 ENGINE WIRE
CAUTION:
Wear insulated gloves.
Note
Insulate the disconnected terminals with insulating tape.
Cover the hole where the cable was connected with tape or equivalent (non-residue type) to prevent entry of foreign matter.
Remove the bolt (A).
Remove the 4 bolts (B), and disconnect the No. 2 engine wire (high voltage cables for the air conditioning compressor) from the inverter with converter assembly.
INSTALL INVERTER COVER
CAUTION:
Wear insulated gloves.
Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
Note
Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter cover.
INSTALL INVERTER TERMINAL COVER
CAUTION:
Wear insulated gloves.
| *1 | Interlock Connector |
Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
Note
Visually confirm that the inverter terminal cover waterproofing rubber is securely installed before installing the inverter terminal cover.
Make sure that the interlock connector is fully engaged.
DISCONNECT WIRE HARNESS
Remove the relay block cover.
Disconnect the connector.
Disengage the 2 claws and remove the No. 1 relay block cover.
Remove the nut.
Disengage the 2 claws and disconnect the wire harness.
| *1 | Wire Harness |
| *2 | Protector |
Temporarily secure the wire harness with the inverter with converter assembly protector as shown in the illustration.
Tech Tips
To prevent the wire harness from getting caught by other components, connect it to the protector before removing the inverter with converter assembly.
DISCONNECT NO. 1 INVERTER COOLING HOSE ASSEMBLY
| *1 | Retainer |
Release the retainer and disconnect the No. 1 inverter cooling hose assembly from the inverter with converter assembly.
Put pieces of cloth into the pipes and in the disconnected hose, or cover the pipes and hoses with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.
DISCONNECT NO. 2 INVERTER COOLING HOSE ASSEMBLY
| *1 | Retainer |
Release the retainer and disconnect the No. 2 inverter cooling hose assembly from the inverter with converter assembly.
Put pieces of cloth into the pipes and in the disconnected hoses, or cover the pipes and hose with plastic bags as shown in the illustration to prevent foreign matter from entering the cooling system and to prevent coolant from spilling near the inverter with converter assembly.
REMOVE INVERTER WITH CONVERTER ASSEMBLY
CAUTION:
Wear insulated gloves.
Remove the 3 bolts and inverter with converter assembly.
Note
Since the inverter with converter assembly is very heavy, 2 people are needed to remove the inverter with converter assembly. When removing the inverter with converter assembly, do not damage the parts around it.
To prevent damage, do not hold the inverter with converter assembly by the connectors.
To prevent damage due to static electricity, do not touch the terminals of the disconnected connectors.
Even after the coolant is drained, coolant remains in the inverter due to its internal structure. Therefore, seal or cover the pipes when removing the inverter so that coolant does not spill out.
REMOVE HIGH VOLTAGE FUSE
CAUTION:
Wear insulated gloves.
Tech Tips
Perform this procedure only when replacement of the high voltage fuse is necessary.
| *1 | Interlock Connector |
Remove the 2 bolts and inverter terminal cover.
Note
Make sure to pull the inverter terminal cover straight up to remove it, because an interlock connector is connected to the bottom of the inverter terminal cover.
Remove the 7 bolts and inverter cover.
Remove the 2 bolts and high voltage fuse from the inverter with converter assembly.
Note
Do not allow any foreign matter or water to enter the inverter with converter assembly.
Temporarily install the inverter cover with the 7 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
Note
Visually confirm that the inverter cover waterproofing rubber is securely installed before installing the inverter cover.
| *1 | Interlock Connector |
Temporarily install the inverter terminal cover with the 2 bolts to prevent any foreign matter or water from entering the inverter with converter assembly.
Note
Visually confirm that the inverter terminal cover waterproofing rubber is securely installed before installing the inverter terminal cover.
Make sure that the interlock connector is fully engaged.