  1. INSPECT AUTO HIGH BEAM SWITCH


    1. Check the resistance


      1. A01V1UVE36
        Text in Illustration
        *a

        Component without harness connected

        (Auto High Beam Switch)

        Measure the resistance according to the value(s) in the table below.

        Standard Resistance
        Tester Connection Switch Condition Specified Condition
        4 (+B) - 1 (E) Auto high beam switch off 10 kΩ or higher
        Auto high beam switch on Below 1 Ω

        If the result is not as specified, replace the auto high beam switch.

    2. Illumination Inspection


      1. A01V1UVE37
        Text in Illustration
        *a

        Component without harness connected

        (Auto High Beam Switch)

        Apply auxiliary battery voltage to the auto high beam switch and check that the switch illuminates.

        OK
        Condition Specified Condition

        Auxiliary battery positive (+) → Terminal 3 (ILL+)

        Auxiliary battery negative (-) → Terminal 2 (ILL-)

        Illuminates

        If the result is not as specified, replace the auto high beam switch.