| DTC Code | DTC Name |
|---|---|
| P0A92-261 | Hybrid Generator Performance |
DESCRIPTION
For a description of MG1 Click here.
| DTC No. | INF Code | DTC Detection Condition | Trouble Area |
|---|---|---|---|
| P0A92 | 261 | Generator magnetic force deterioration or same phase short circuit |
|
WIRING DIAGRAM
Refer to the wiring diagram for DTC P0AA6-526 Click here.
Refer to the wiring diagram for DTC P321E-318 Click here.
CAUTION / NOTICE / HINT
CAUTION:
Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, turn the ignition switch off and take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.
Tech Tips
Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.
Tech Tips
After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.
Drive the vehicle until the cumulative traveling time using the engine is a few minutes. (It is not required to keep driving using the engine.)
PROCEDURE
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A1A (all INF codes)*1 | Generator Control Module |
| P0A1B (all INF codes)*1 | Drive Motor "A" Control Module |
| P0A1D (all INF codes)*1 | Hybrid Powertrain Control Module |
| P0A3F-243 | Drive Motor "A" Position Sensor Circuit |
| P0A40-500 | Drive Motor "A" Position Sensor Circuit Range/Performance |
| P0A41-245 | Drive Motor "A" Position Sensor Circuit Low |
| P0A4B-253 | Generator Position Sensor Circuit |
| P0A4C-513 | Generator Position Sensor Circuit Range/Performance |
| P0A4D-255 | Generator Position Sensor Circuit Low |
| P0A51-174 | Drive Motor "A" Current Sensor Circuit |
| P0A60 (all INF codes)*1 | Drive Motor "A" Phase V Current |
| P0A63 (all INF codes)*1 | Drive Motor "A" Phase W Current |
| P0A72 (all INF codes)*1 | Generator Phase V Current |
| P0A75 (all INF codes)*1 | Generator Phase W Current |
| P0A78-266, 267, 306, 586 | Drive Motor "A" Inverter Performance |
| P0A7A-203, 344 | Generator Inverter Performance |
| P0A90-509 | Drive Motor "A" Performance |
| P0A92-521 | Hybrid Generator Performance |
| P0A94-585, 587, 589, 590 | DC / DC Converter Performance |
| P0AA6 (all INF codes)*1 | Hybrid Battery Voltage System Isolation Fault |
| P0C76-523 | Hybrid Battery System Discharge Time Too Long |
| P3004-132 | High Voltage Power Resource |
Tech Tips
*1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.
P0A92-261 may be output due to a malfunction which causes the DTCs in the table above to be output. In this case, first troubleshoot the output DTCs in the table above. Then, perform a reproduction test to check that no DTCs are output.
Turn the ignition switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK DTC OUTPUT (HYBRID CONTROL)
Connect the GTS to the DLC3.
Turn the ignition switch to ON (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
| DTC No. | Relevant Diagnosis |
|---|---|
| P0A90-251 | Drive Motor "A" Performance |
Tech Tips
When the DTCs listed in the table above are also output, there may be a short between the HSDN (MG shut down signal) circuit and power circuit.
Turn the ignition switch off.
| B |
|
SIMULATION TEST Click here |
| A |
|
CHECK POWER MANAGEMENT CONTROL ECU
Turn the ignition switch to ON (IG).
| *a | Component with harness connected (Power Management Control ECU) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Turn the ignition switch off.
| NG |
|
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY) Click here |
| OK |
|
SIMULATION TEST
Turn the ignition switch to ON (READY).
Leave the vehicle for 1 minute with the engine on (with MG1 rotating).
Tech Tips
If the accelerator pedal is depressed with shift lever in (P), the engine will start.
Connect the GTS to the DLC3.
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Check if DTCs are output.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Turn the ignition switch off.
| B |
|
GO TO DTC CHART (HYBRID CONTROL SYSTEM) Click here |
| A |
|
CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.
Note
Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.
| OK |
|---|
| The connectors are connected securely and there are no contact pressure problems. |
Tech Tips
When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.
| NG |
|
CONNECT SECURELY |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter terminal cover from the inverter with converter assembly.
Remove the inverter cover from the inverter with converter assembly.
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| Bolt A |
| T=8.0 N*m (82 kgf*cm, 71 in.*lbf) |
| Bolt B |
| T=9.2 N*m (94 kgf*cm, 81 ft.*lbf) |
Note
Make sure that the tightening torque of the bolt B is between 6.4 and 12 N*m (65 and 122 kgf*cm, 57 and 106 in.*lbf).
Disconnect the motor cable (for MG1) from the inverter with converter assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
Connect the motor cable (for MG1) to the inverter with converter assembly.
Install the inverter cover.
Install the inverter terminal cover.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK HYBRID VEHICLE TRANSAXLE ASSEMBLY (MOTOR CABLE (FOR MG1) CONNECTION CONDITION)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the inverter with converter assembly Click here.
Check that the bolts for the motor cable (for MG1) are tightened to the specified torque, the motor cable (for MG1) is connected securely, and there are no contact problems.
| Specified Condition |
|---|
| Bolt A |
| T=19.5 N*m (199 kgf*cm, 14 ft.*lbf) |
| Bolt B |
| T=10 N*m (102 kgf*cm, 7 ft.*lbf) |
Note
Make sure that the tightening torque of the bolt A is between 13.5 and 25 N*m (138 and 255 kgf*cm, 10 and 18 ft.*lbf).
Make sure that the tightening torque of the bolt B is between 8 and 12 N*m (82 and 122 kgf*cm, 71 and 106 in.*lbf).
Disconnect the motor cable (for MG1) from the hybrid vehicle transaxle assembly.
Check for arc marks at the terminals for the motor cable (for MG1).
| Result | |||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||
Connect the motor cable (for MG1) to the hybrid vehicle transaxle assembly.
Install the inverter with converter assembly.
| B |
|
REPLACE MALFUNCTIONING PARTS |
| C |
|
CONNECT SECURELY |
| A |
|
CHECK MOTOR CABLE (FOR MG1)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the motor cable Click here.
| *1 | Shield Ground |
| *a | Motor Cable (for MG1) (Inverter with Converter Assembly Side) |
| *b | Motor Cable (for MG1) (Hybrid Vehicle Transaxle Assembly Side) |
Using a megohmmeter set to 500 V, measure the resistance according to the value(s) in the table below.
Note
Be sure to set the megohmmeter to 500 V when performing this test. Using a setting higher than 500 V can result in damage to the component being inspected.
| Standard Resistance | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Note
Wrap the connector W1 terminal of the motor cable (for MG1) with insulating tape to prevent it from coming into contact with body ground
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Install the motor cable.
| OK |
|
REPLACE HYBRID VEHICLE TRANSAXLE ASSEMBLY Click here |
| NG |
|
REPLACE MOTOR CABLE Click here |
CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - INVERTER WITH CONVERTER ASSEMBLY)
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the inverter with converter assembly connector.
Disconnect the power management control ECU connector.
Connect the cable to the negative (-) auxiliary battery terminal.
Turn the ignition switch to ON (IG).
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| *A | w/ Power Switch |
| *a | Front view of wire harness connector (to Inverter with Converter Assembly) |
| *b | Rear view of wire harness connector (to Power Management Control ECU) |
Note
Turning the ignition switch to ON (IG) with the connector disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.
Turn the ignition switch off.
Disconnect the cable from the negative (-) auxiliary battery terminal.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (w/ Power Switch) | |||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (w/o Power Switch) | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the inverter with converter assembly connector.
Connect the power management control ECU connector.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK INVERTER WITH CONVERTER ASSEMBLY
CAUTION:
Be sure to wear insulated gloves.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.
Disconnect the inverter with converter assembly connector.
| *a | Component without harness connected (Inverter with Converter Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Connect the inverter with converter assembly connector.
| OK |
|
REPLACE POWER MANAGEMENT CONTROL ECU Click here |
| NG |
|
REFER TO REPLACE INVERTER WITH CONVERTER ASSEMBLY PARTS Click here |