HYBRID CONTROL SYSTEM, Diagnostic DTC:P0A7A-518, P0A7A-811

DTC Code DTC Name
P0A7A-518 Generator Inverter Performance
P0A7A-811 Generator Inverter Performance

DESCRIPTION

For a description of the inverter Click here.

If the generator inverter overheats, has a circuit malfunction or has an internal short, the inverter transmits this information to the MG ECU via the generator inverter fail signal line.

If an abnormal amount of current flows through the generator inverter, the MG ECU detects it and sends a signal to inform the power management control ECU of the malfunction.

DTC No. INF Code DTC Detection Condition Trouble Area
P0A7A 518 Generator inverter fail signal detection (overcurrent due to hybrid vehicle transaxle assembly malfunction)
  • Inverter with converter assembly

  • Hybrid vehicle transaxle assembly

  • Wire harness or connector

811 Abnormal generator current value detection (hybrid vehicle transaxle assembly malfunction)

WIRING DIAGRAM

Refer to the wiring diagram for DTC P0A1A-200 Click here.

CAUTION / NOTICE / HINT

CAUTION:


  • Before inspecting the high-voltage system or disconnecting the low voltage connector of the inverter with converter assembly, turn the ignition switch off and take safety precautions such as wearing insulated gloves and removing the service plug grip to prevent electrical shocks. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.

  • After removing the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals. After waiting for 10 minutes, check the voltage at the terminals in the inspection point in the inverter with converter assembly. The voltage should be 0 V before beginning work Click here.

    Tech Tips

    Waiting for at least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.

Note

After turning the ignition switch off, waiting time may be required before disconnecting the cable from the negative (-) auxiliary battery terminal. Therefore, make sure to read the disconnecting the cable from the negative (-) auxiliary battery terminal notices before proceeding with work Click here.

Tech Tips

After the repair, clear the DTCs and perform the following procedure to check that DTCs are not output.


  1. Turn the ignition switch to ON (READY) and wait for 5 seconds or more.

  2. Drive the vehicle for approximately 10 minutes mainly using the engine.

PROCEDURE


  1. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Result
      Result Proceed to
      P0A7A-203 is not output. A
      P0A7A-203 is also output. B

      Note


      • If P0A7A-203 is output, troubleshoot it first. After completing the troubleshooting for P0A7A-203, return to perform troubleshooting for this DTC.

      • Parts repaired or replaced during troubleshooting for P0A7A-203 do not need to be re-inspected in this diagnosis procedure.

    5. Turn the ignition switch off.


    B
    A
  2. CHECK DTC OUTPUT (HYBRID CONTROL)


    1. Connect the GTS to the DLC3.

    2. Turn the ignition switch to ON (IG).

    3. Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.

    4. Check if DTCs are output.

      Tech Tips


      • If P0A7A-203 was not output in step 1 of this diagnosis procedure, check Table 1 below.

      • If P0A7A-203 was output in step 1 of this diagnosis procedure, repair that DTC first, then check Table 2 below.

      Result
      Result Proceed to
      Only P0A7A-518 or 811 is output, or DTCs other than the ones in the table below are also output. A
      Any of the following DTCs are also output. B
      Table 1
      DTC No. Relevant Diagnosis
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72 (all INF codes)*1 Generator Phase V Current
      P0A75 (all INF codes)*1 Generator Phase W Current
      P0A78-266, 267, 586 Drive Motor "A" Inverter Performance
      P0A94-585, 587, 589, 590 DC / DC Converter Performance
      P0C76-523 Hybrid Battery System Discharge Time Too Long
      Table 2
      DTC No. Relevant Diagnosis
      P0A1A (all INF codes)*1 Generator Control Module
      P0A1B (all INF codes)*1 Drive Motor "A" Control Module
      P0A1D (all INF codes)*1 Hybrid Powertrain Control Module
      P0A3F-243 Drive Motor "A" Position Sensor Circuit
      P0A40-500 Drive Motor "A" Position Sensor Circuit Range/Performance
      P0A41-245 Drive Motor "A" Position Sensor Circuit Low
      P0A4B-253 Generator Position Sensor Circuit
      P0A4C-513 Generator Position Sensor Circuit Range/Performance
      P0A4D-255 Generator Position Sensor Circuit Low
      P0A60 (all INF codes)*1 Drive Motor "A" Phase V Current
      P0A63 (all INF codes)*1 Drive Motor "A" Phase W Current
      P0A72-333 Generator Phase V Current
      P0A75-341 Generator Phase W Current
      P0A78-266, 267, 586 Drive Motor "A" Inverter Performance
      P0A94-585, 587, 589, 590 DC / DC Converter Performance
      P0C76-523 Hybrid Battery System Discharge Time Too Long

      Tech Tips


      • *1: If any INF codes are output for this DTC, refer to the corresponding diagnostic procedure.

      • P0A7A-518 or P0A7A-811 may be set due to a malfunction which also causes DTCs in the preceding table to be set. In this case, first troubleshoot the output DTCs in the preceding table. Then, perform a test to attempt to reproduce the problems, and check that no DTCs are output.

    5. Turn the ignition switch off.


    B
    A
  3. CHECK CONNECTOR CONNECTION CONDITION (INVERTER WITH CONVERTER ASSEMBLY CONNECTOR)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. A01UY1U

      Check the connector connections and contact pressure of the low voltage connectors of the inverter with converter assembly Click here.

      Note

      Before disconnecting the connector, confirm that it is properly connected by checking that the locking claws are engaged and that the connector does not pull out.

      OK
      The connectors are connected securely and there are no contact pressure problems.

      Tech Tips

      When connecting the connector, insert it with the locking lever in the raised position. Rotate the lever downward and make sure that the connector is pulled into its socket. When the locking lever is in its fully closed position, a click will be heard as its locking claws engage. After the click is heard, pull up on the connector to confirm that it is properly connected.


    NG
    OK
  4. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the inverter with converter assembly connector.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the ignition switch to ON (IG).

    5. A004F6DE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      C28-11 (GRF) - Body ground Ignition switch ON (IG) Below 1 V
      C28-12 (GRFG) - Body ground Ignition switch ON (IG) Below 1 V
      C28-7 (GSN) - Body ground Ignition switch ON (IG) Below 1 V
      C28-8 (GSNG) - Body ground Ignition switch ON (IG) Below 1 V
      C28-10 (GCS) - Body ground Ignition switch ON (IG) Below 1 V
      C28-9 (GCSG) - Body ground Ignition switch ON (IG) Below 1 V

      Note

      Turning the ignition switch to ON (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the ignition switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Connect the inverter with converter assembly connector.


    NG
    OK
  5. CHECK GENERATOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the inverter with converter assembly connector.

    3. A004F6DE02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      C28-11 (GRF) - C28-12 (GRFG) Ignition switch off 7.1 to 21.6 Ω
      C28-7 (GSN) - C28-8 (GSNG) Ignition switch off 13.7 to 34.5 Ω
      C28-10 (GCS) - C28-9 (GCSG) Ignition switch off 12.8 to 32.4 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      C28-11 (GRF) or C28-12 (GRFG) - Body ground and other terminals Ignition switch off 10 kΩ or higher
      C28-7 (GSN) or C28-8 (GSNG) - Body ground and other terminals Ignition switch off 10 kΩ or higher
      C28-10 (GCS) or C28-9 (GCSG) - Body ground and other terminals Ignition switch off 10 kΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  6. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the inverter with converter assembly connector.

    3. Connect the cable to the negative (-) auxiliary battery terminal.

    4. Turn the ignition switch to ON (IG).

    5. A004E74E02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Switch Condition Specified Condition
      C28-1 (MRF) - Body ground Ignition switch ON (IG) Below 1 V
      C28-2 (MRFG) - Body ground Ignition switch ON (IG) Below 1 V
      C28-3 (MSN) - Body ground Ignition switch ON (IG) Below 1 V
      C28-4 (MSNG) - Body ground Ignition switch ON (IG) Below 1 V
      C28-6 (MCS) - Body ground Ignition switch ON (IG) Below 1 V
      C28-5 (MCSG) - Body ground Ignition switch ON (IG) Below 1 V

      Note

      Turning the ignition switch to ON (IG) with the low voltage connector of the inverter with converter assembly disconnected causes other DTCs to be stored. Clear the DTCs after performing this inspection.

    6. Turn the ignition switch off.

    7. Disconnect the cable from the negative (-) auxiliary battery terminal.

    8. Connect the inverter with converter assembly connector.


    NG
    OK
  7. CHECK MOTOR RESOLVER

    CAUTION:

    Be sure to wear insulated gloves.


    1. Check that the service plug grip is not installed.

      Note

      After removing the service plug grip, do not turn the ignition switch to ON (READY), unless instructed by the repair manual because this may cause a malfunction.

    2. Disconnect the inverter with converter assembly connector.

    3. A004E74E02
      Text in Illustration
      *a

      Front view of wire harness connector

      (to Inverter with Converter Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Switch Condition Specified Condition
      C28-1 (MRF) - C28-2 (MRFG) Ignition switch off 7.1 to 21.6 Ω
      C28-3 (MSN) - C28-4 (MSNG) Ignition switch off 13.7 to 34.5 Ω
      C28-6 (MCS) - C28-5 (MCSG) Ignition switch off 12.8 to 32.4 Ω
      Standard Resistance (Check for Short)
      Tester Connection Switch Condition Specified Condition
      C28-1 (MRF) or C28-2 (MRFG) - Body ground and other terminals Ignition switch off 10 kΩ or higher
      C28-3 (MSN) or C28-4 (MSNG) - Body ground and other terminals Ignition switch off 10 kΩ or higher
      C28-6 (MCS) or C28-5 (MCSG) - Body ground and other terminals Ignition switch off 10 kΩ or higher
    4. Connect the inverter with converter assembly connector.


    NG
    OK
  8. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. A004G3E

      Check the connection of the generator resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  9. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. A004G5V

      Check the connection of the motor resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    OK
    NG
  10. CHECK CONNECTOR CONNECTION CONDITION (GENERATOR RESOLVER CONNECTOR)


    1. A004G3E

      Check the connection of the generator resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  11. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - GENERATOR RESOLVER)


    1. A004G3E

      Disconnect the resolver connector.

    2. A004EDMC10
      *a

      Component without harness connected

      (Generator resolver (Hybrid Vehicle Transaxle Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      C24-1 (GRF) - C24-5 (GRFG) Ignition switch off 9.5 to 15.5 Ω
      C24-2 (GSN) - C24-6 (GSNG) Ignition switch off 15.0 to 27.0 Ω
      C24-3 (GCS) - C24-7 (GCSG) Ignition switch off 14.0 to 26.0 Ω

      Tech Tips

      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

      R20 = Rt / {1 + 0.00393 X (T - 20)}

      The calculation is based on the following:

      R20: Resistance at 20°C (68°F) (mΩ)

      Rt: Measured resistance (mΩ)

      T: Temperature when the resistance is measured (°C (°F).)

      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      C24-1 (GRF) - Body ground and other terminals (except C24-5 (GRFG)) Power switch off 1 MΩ or higher
      C24-5 (GRFG) - Body ground and other terminals (except C24-1 (GRF)) Power switch off 1 MΩ or higher
      C24-2 (GSN) - Body ground and other terminals (except C24-6 (GSNG)) Power switch off 1 MΩ or higher
      C24-6 (GSNG) - Body ground and other terminals (except C24-2 (GSN)) Power switch off 1 MΩ or higher
      C24-3 (GCS) - Body ground and other terminals (except C24-7 (GCSG)) Power switch off 1 MΩ or higher
      C24-7 (GCSG) - Body ground and other terminals (except C24-3 (GCS)) Power switch off 1 MΩ or higher
    3. Reconnect the resolver connector.


    OK
    NG
  12. CHECK CONNECTOR CONNECTION CONDITION (MOTOR RESOLVER CONNECTOR)


    1. A004G5V

      Check the connection of the motor resolver connector.

      OK
      The connector is connected securely and there are no contact problems.

    NG
    OK
  13. CHECK HARNESS AND CONNECTOR (INVERTER WITH CONVERTER ASSEMBLY - MOTOR RESOLVER)


    1. A004G5V

      Disconnect the resolver connector.

    2. A004EWLC03
      *a

      Component without harness connected

      (Motor Resolver (Hybrid Vehicle Transaxle Assembly))

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance (Check for Open)
      Tester Connection Condition Specified Condition
      C26-3 (MRF) - C26-6 (MRFG) Ignition switch off 9.5 to 15.5 Ω
      C26-1 (MSN) - C26-4 (MSNG) Ignition switch off 15.0 to 27.0 Ω
      C26-2 (MCS) - C26-5 (MCSG) Ignition switch off 14.0 to 26.0 Ω

      Tech Tips

      To correct the variation of the measured resistance due to temperature, use the following formula to calculate the resistance at 20°C (68°F).

      R20 = Rt / {1 + 0.00393 X (T - 20)}

      The calculation is based on the following:

      R20: Resistance at 20°C (68°F) (mΩ)

      Rt: Measured resistance (mΩ)

      T: Temperature when the resistance is measured (°C (°F).)

      Standard Resistance (Check for Short)
      Tester Connection Condition Specified Condition
      C26-3 (MRF) - Body ground and other terminals (except C26-6 (MRFG)) Power switch off 1 MΩ or higher
      C26-6 (MRFG) - Body ground and other terminals (except C26-3 (MRF)) Power switch off 1 MΩ or higher
      C26-1 (MSN) - Body ground and other terminals (except C26-4 (MSNG)) Power switch off 1 MΩ or higher
      C26-4 (MSNG) - Body ground and other terminals (except C26-1 (MSN)) Power switch off 1 MΩ or higher
      C26-2 (MCS) - Body ground and other terminals (except C26-5 (MCSG)) Power switch off 1 MΩ or higher
      C26-5 (MCSG) - Body ground and other terminals (except C26-2 (MCS)) Power switch off 1 MΩ or higher
    3. Reconnect the resolver connector.


    OK
    NG