| *1 | Power Management Control ECU | - | - |
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Specified Condition |
|---|---|---|---|---|
| A26-2 (+B2) - F55-6 (E1) | L - BR | Power source | Ignition switch ON (IG) | 11 to 14 V |
| A26-11 (VLO) - F55-6 (E1) | R - BR | DC/DC operation monitor / voltage change signal | Ignition switch ON (IG) | Pulse generation (Waveform 1) |
| A26-13 (IWP) - F55-6 (E1) | G - BR | Inverter water pump assembly signal | Ignition switch ON (READY) | Pulse generation (Waveform 2) |
| A26-14 (NIWP) - F55-6 (E1) | P - BR | Inverter water pump assembly signal | Ignition switch ON (READY) | Pulse generation (Waveform 2) |
| A26-15 (BL) - F55-6 (E1) | R - BR | Back up light | Ignition switch ON (IG), shift lever in R | 11 to 14 V |
| A26-19 (CLK) - F55-6 (E1) | G - BR | A/C communication signal | Ignition switch ON (READY), air conditioning system stopped | Pulse generation (Waveform 3) |
| A26-20 (STB) - F55-6 (E1) | W - BR | A/C communication signal | Ignition switch ON (READY), air conditioning system stopped | Pulse generation (Waveform 3) |
| A26-21 (NODD) - F55-6 (E1) | W - BR | DC/DC operation | DC/DC converter operating normally | 5 to 7 V |
| DC/DC converter not operating normally | 2 to 4 V | |||
| DC/DC converter operating prohibited | 0.1 to 0.5 V | |||
| A26-24 (MMT) - A26-25 (MMTG) | L - BR | Motor temperature sensor | Ignition switch ON (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Ignition switch ON (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | |||
| A26-26 (GMT) - A26-27 (GMTG) | B - R | Generator temperature sensor | Ignition switch ON (IG), temperature 25°C (77°F) | 3.6 to 4.6 V |
| Ignition switch ON (IG), temperature 60°C (140°F) | 2.2 to 3.2 V | |||
| A26-29 (SI0) - F55-6 (E1) | Y - BR | HV battery blower fan operation signal | Ignition switch ON (IG), during Active Test | Pulse generation (Waveform 4) |
| A26-30 (ETI) - F55-6 (E1) | R - BR | A/C communication signal | Ignition switch ON (READY), air conditioning system stopped | Pulse generation (Waveform 3) |
| A26-31 (ITE) - F55-6 (E1) | Y - BR | A/C communication signal | Ignition switch ON (READY), air conditioning system stopped | Pulse generation (Waveform 3) |
| A26-32 (ILK) - F55-6 (E1) | V - BR | Interlock switch | Ignition switch ON (IG), inverter terminal cover, frame wire connector (to inverter with converter assembly) and service plug grip installed correctly | 0 to 1.5 V |
| Ignition switch ON (IG), inverter terminal cover, frame wire connector (to inverter with converter assembly) or service plug grip not installed | 11 to 14 V | |||
| A27-1 (IG2) - F55-6 (E1) | V - BR | Power source | Ignition switch ON (IG) | 11 to 14 V |
| A27-2 (IG2D) - F55-6 (E1) | P - BR | IG2 relay | Ignition switch ON (IG) | 11 to 14 V |
| A27-5 (+B1) - F55-6 (E1) | L - BR | Power source | Ignition switch ON (IG) | 11 to 14 V |
| A27-6 (MREL) - F55-6 (E1) | BE - BR | Main relay | Ignition switch ON (IG) | 11 to 14 V |
| A27-7 (ST1-) - F55-6 (E1) | BR - BR | Brake cancel switch | Ignition switch ON (IG), brake pedal depressed | 0 to 1.5 V |
| Ignition switch ON (IG), brake pedal released | 11 to 14 V | |||
| A27-8 (N) - F55-6 (E1) | Y - BR | Shift lever position signal | Ignition switch ON (IG), shift lever in N | 11 to 14 V |
| Ignition switch ON (IG), shift lever not in N | 0.5 to 1.5 V | |||
| A27-9 (PR) - F55-6 (E1) | V - BR | Shift lever position signal | Ignition switch ON (IG), shift lever in P or R | 11 to 14 V |
| Ignition switch ON (IG), shift lever not in P or R | 0.5 to 1.5 V | |||
| A27-11 (DB1) - F55-6 (E1) | L - BR | Shift lever position signal | Ignition switch ON (IG), shift lever in D or B | 11 to 14 V |
| Ignition switch ON (IG), shift lever not in D or B | 0.5 to 1.5 V | |||
| A27-13 (DB2) - F55-6 (E1) | B - BR | Shift lever position signal | Ignition switch ON (IG), shift lever in D or B | 11 to 14 V |
| Ignition switch ON (IG), shift lever not in D or B | 0.5 to 1.5 V | |||
| A27-14 (R) - F55-6 (E1) | SB - BR | Shift lever position signal | Ignition switch ON (IG), shift lever in R | 11 to 14 V |
| Ignition switch ON (IG), shift lever not in R | 0.5 to 1.5 V | |||
| A27-15 (P) - F55-6 (E1) | BE - BR | Shift lever position signal | Ignition switch ON (IG), shift lever in P | 11 to 14 V |
| Ignition switch ON (IG), shift lever not in P | 0.5 to 1.5 V | |||
| A27-16 (PNB) - F55-6 (E1) | G - BR | Shift lever position signal | Ignition switch ON (IG), shift lever in P, N or B | 11 to 14 V |
| A27-18 (VCP1) - A27-34 (EP1) | Y - B | Accelerator pedal sensor assembly power source (for VPA1) | Ignition switch ON (IG) | 4.5 to 5.5 V |
| A27-19 (VCP2) - A27-35 (EP2) | G - R | Accelerator pedal sensor assembly power source (for VPA2) | Ignition switch ON (IG) | 4.5 to 5.5 V |
| A27-20 (CLK-) - F55-6 (E1) | W - BR | MG communication clock signal | Ignition switch ON (READY) | Pulse generation (Waveform 5) |
| A27-21 (CLK+) - F55-6 (E1) | B - BR | MG communication clock signal | Ignition switch ON (READY) | Pulse generation (Waveform 5) |
| A27-23 (STP) - F55-6 (E1) | G - BR | Stop light switch | Brake pedal depressed | 11 to 14 V |
| Brake pedal released | 0 to 1.5 V | |||
| A27-24 (HTM+) - F55-6 (E1) | B - BR | Communication signal from power management control ECU to MG ECU | Ignition switch ON (IG) | Pulse generation (Waveform 6) |
| A27-25 (HTM-) - F55-6 (E1) | W - BR | Communication signal from power management control ECU to MG ECU | Ignition switch ON (IG) | Pulse generation (Waveform 6) |
| A27-26 (VPA1) - A27-34 (EP1) | L - B | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Ignition switch ON (IG), accelerator pedal released | 0.4 to 1.4 V |
| Ignition switch ON (IG) engine stopped, shift lever in P accelerator pedal fully depressed | 2.6 to 4.5 V | |||
| A27-27 (VPA2) - A27-35 (EP2) | W - R | Accelerator pedal sensor assembly (for accelerator pedal position detection) | Ignition switch ON (IG), accelerator pedal released | 1.0 to 2.2 V |
| Ignition switch ON (IG) engine stopped, shift lever in P accelerator pedal fully depressed | 3.4 to 5.3 V | |||
| A27-29 (MTH-) - F55-6 (E1) | W - BR | Communication signal from MG ECU to power management control ECU | Ignition switch ON (IG) | Pulse generation (Waveform 7) |
| A27-30 (MTH+) - F55-6 (E1) | B - BR | Communication signal from MG ECU to power management control ECU | Ignition switch ON (IG) | Pulse generation (Waveform 7) |
| A27-31 (HSDN) - F55-6 (E1) | B - BR | MG ECU shutdown signal | Ignition switch ON (READY) | 0 to 1.5 V |
| A27-32 (REQ-) - F55-6 (E1) | W - BR | MG ECU communication request signal | Ignition switch ON (IG) | Pulse generation (Waveform 8) |
| A27-33 (REQ+) - F55-6 (E1) | B - BR | MG ECU communication request signal | Ignition switch ON (IG) | Pulse generation (Waveform 8) |
| F55-1 (AM22)*1 - F55-6 (E1) | B - BR | Constant power source | Power switch On (IG) | 11 to 14 V |
| Power switch On (Ready) | 11 to 15.5 V | |||
| F55-1 (BATT)*2 - F55-6 (E1) | BE - BR | Constant power source | Ignition switch ON (IG) | 11 to 14 V |
| Ignition switch ON (READY) | 11 to 15.5 V | |||
| F55-2 (SMRG) - F55-5 (E01) | Y - W-B | System main relay operation signal | Ignition switch ON (IG)→Ignition switch ON (READY) | Pulse generation (Waveform 9) |
| F55-3 (SMRP) - F55-5 (E01) | W - W-B | System main relay operation signal | Ignition switch ON (IG)→Ignition switch ON (READY) | Pulse generation (Waveform 9) |
| F55-4 (SMRB) - F55-5 (E01) | SB - W-B | System main relay operation signal | Ignition switch ON (IG)→Ignition switch ON (READY) | Pulse generation (Waveform 9) |
| F55-7 (SSW1)*1 - F55-6 (E1) | V - BR | Power switch | Power switch pressed and held | 0 to 1.5 V |
| F55-11 (TC) - F55-6 (E1) | L - BR | Diagnosis terminal | Ignition switch ON (IG) | 11 to 14 V |
| F55-13 (EVSW) - F55-6 (E1) | B - BR | EV switch signal | Ignition switch ON (IG), EV switch not operated | 11 to 14 V |
| Ignition switch ON (IG), EV switch operated | 0 to 1.5 V | |||
| F55-14 (SPDI) - F55-6 (E1) | L - BR | Vehicle speed signal | Driving at approximately 20 km/h (12 mph) with ignition switch ON (READY) | Pulse generation (Waveform 10) |
| F55-15 (P2) - F55-6 (E1) | Y - BR | Shift P signal | Ignition switch ON (IG) | Pulse generation (Waveform 11) |
| F55-28 (THB) - F55-30 (ETHB) | L - V | Auxiliary battery temperature | Ignition switch ON (IG), auxiliary battery temperature 25°C (77°F) | 1.7 to 2.3 V |
| Ignition switch ON (IG), auxiliary battery temperature 60°C (140°F) | 0.6 to 0.9 V | |||
| F55-29 (ABFS) - F55-6 (E1) | L - BR | Airbag activation signal | Ignition switch ON (READY) | Pulse generation (Waveform 12) |
| F55-32 (BTH+) - F55-6 (E1) | R - BR | Communication signal from battery smart unit to power management control ECU | Ignition switch ON (IG) | Pulse generation (Waveform 13) |
| F55-33 (BTH-) - F55-6 (E1) | G - BR | Communication signal from battery smart unit to power management control ECU | Ignition switch ON (IG) | Pulse generation (Waveform 13) |
| F56-1 (ACCD)*1 - F55-6 (E1) | L - BR | ACC relay | Power switch On (ACC) | 11 to 14 V |
| F56-2 (IG1D)*1 - F55-6 (E1) | SB - BR | IG1 relay | Power switch On (IG) | 11 to 14 V |
| F56-7 (AM21)*1 - F55-6 (E1) | B - BR | Constant power source | Power switch On (IG) | 11 to 14 V |
| Power switch On (Ready) | 11 to 15.5 V | |||
| F56-11 (LIN2)*1 - F55-6 (E1) | BE - BR | LIN communication signal | Power switch On (IG) | Pulse generation |
| F56-17 (SSW2)*1 - F55-6 (E1) | G - BR | Power switch | Power switch pressed and held | 0 to 1.5 V |
| F56-24 (CA1L) - F55-6 (E1) | W - BR | CAN communication signal | Ignition switch ON (IG) | Pulse generation (Waveform 14) |
| F56-25 (CA1H) - F55-6 (E1) | BE - BR | CAN communication signal | Ignition switch ON (IG) | Pulse generation (Waveform 14) |
| F56-30 (CA3N) - F55-6 (E1) | W - BR | CAN communication signal | Ignition switch ON (IG) | Pulse generation (Waveform 15) |
| F56-31 (CA3P) - F55-6 (E1) | Y - BR | CAN communication signal | Ignition switch ON (IG) | Pulse generation (Waveform 15) |
*1: w/ Power Switch
*2: w/o Power Switch
Oscilloscope waveforms
Tech Tips
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (DC/DC operation monitor / voltage change signal)
| Item | Content |
|---|---|
| Terminal | A26-11 (VLO) - F55-6 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Ignition switch ON (IG) |
Tech Tips
The cycle will vary depending on the specified voltage of the hybrid vehicle converter.
Waveform 2 (inverter water pump assembly signal)
| Item | Content |
|---|---|
| Terminal | CH1: A26-13 (IWP) - F55-6 (E1) CH2: A26-14 (NIWP) - F55-6 (E1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Ignition switch ON (READY) |
Waveform 3 (A/C communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: A26-19 (CLK) - F55-6 (E1) CH2: A26-31 (ITE) - F55-6 (E1) CH3: A26-30 (ETI) - F55-6 (E1) CH4: A26-20 (STB) - F55-6 (E1) |
| Equipment Setting | 10 V/DIV., 100 ms./DIV. |
| Condition | Ignition switch ON (READY), air conditioning system stopped |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 4 (HV battery blower fan operation signal)
| Item | Content |
|---|---|
| Terminal | A26-29 (SI0) - F55-6 (E1) |
| Equipment Setting | 5 V/DIV., 500 ms./DIV. |
| Condition | Ignition switch ON (IG), during Active Test |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 5 (MG communication clock signal)(Reference)
| Item | Content |
|---|---|
| Terminal | CH1: A27-21 (CLK+) - F55-6 (E1) CH2: A27-20 (CLK-) - F55-6 (E1) |
| Equipment Setting | 1 V/DIV., 1 μs./DIV. |
| Condition | Ignition switch ON (READY) |
Waveform 6 (communication signal from power management control ECU to MG ECU)
| Item | Content |
|---|---|
| Terminal | CH1: A27-24 (HTM+) - F55-6 (E1) CH2: A27-25 (HTM-) - F55-6 (E1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Ignition switch ON (IG) |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 7 (communication signal from MG ECU to power management control ECU)
| Item | Content |
|---|---|
| Terminal | CH1: A27-30 (MTH+) - F55-6 (E1) CH2: A27-29 (MTH-) - F55-6 (E1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Ignition switch ON (IG) |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 8 (MG ECU communication request signal)
| Item | Content |
|---|---|
| Terminal | CH1: A27-33 (REQ+) - F55-6 (E1) CH2: A27-32 (REQ-) - F55-6 (E1) |
| Equipment Setting | 1 V/DIV., 1 ms./DIV. |
| Condition | Ignition switch ON (IG) |
Waveform 9 (system main relay operation signal)
| Item | Content |
|---|---|
| Terminal | CH1: F55-3 (SMRP) - F55-5 (E01) CH2: F55-4 (SMRB) - F55-5 (E01) CH3: F55-2 (SMRG) - F55-5 (E01) |
| Equipment Setting | 10 V/DIV., 200 ms./DIV. |
| Condition | Ignition switch ON (IG) → Ignition switch ON (READY) |
Waveform 10 (vehicle speed signal)
| Item | Content |
|---|---|
| Terminal | F55-14 (SPDI) - F55-6 (E1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Driving at approximately 20 km/h (12 mph) with ignition switch ON (READY) |
Tech Tips
The higher the vehicle speed, the shorter the cycle.
Waveform 11 (shift P signal)
| Item | Content |
|---|---|
| Terminal | F55-15 (P2) - F55-6 (E1) |
| Equipment Setting | 5 V/DIV., 10 ms./DIV. |
| Condition | Ignition switch ON (IG) |
Waveform 12 (airbag activation signal)
| Item | Content |
|---|---|
| Terminal | F55-29 (ABFS) - F55-6 (E1) |
| Equipment Setting | 5 V/DIV., 500 ms./DIV. |
| Condition | Ignition switch ON (READY) |
Waveform 13 (communication signal from battery smart unit to power management control ECU)
| Item | Content |
|---|---|
| Terminal | CH1: F55-32 (BTH+) - F55-6 (E1) CH2: F55-33 (BTH-) - F55-6 (E1) |
| Equipment Setting | 2 V/DIV., 500 μs./DIV. |
| Condition | Ignition switch ON (IG) |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 14 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: F56-25 (CA1H) - F55-6 (E1) CH2: F56-24 (CA1L) - F55-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Ignition switch ON (IG) |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 15 (CAN communication signal)
| Item | Content |
|---|---|
| Terminal | CH1: F56-31 (CA3P) - F55-6 (E1) CH2: F56-30 (CA3N) - F55-6 (E1) |
| Equipment Setting | 1 V/DIV., 50 μs./DIV. |
| Condition | Ignition switch ON (IG) |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
| *1 | Inverter with Converter Assembly | - | - |
Tech Tips
Since the inverter with converter assembly uses waterproof connectors, the voltage and waveform cannot be inspected directly. Standard voltage readings and waveforms are indicated for reference only.
| Terminal No. (Symbol) |
Wiring Color | Terminal Description | Condition | Standard Condition |
|---|---|---|---|---|
| A33-1 (IGCT) - A33-28 (GND1) | B - W-B | MG ECU power source | Ignition switch ON (IG) | 11 to 14 V |
| A33-2 (IDH) - A33-28 (GND1) | L - W-B | PTC heater prohibit signal | Ignition switch ON (IG) | 4 to 6 V |
| A33-3 (VLO) - A33-28 (GND1) | R - W-B | DC/DC operation monitor / voltage change signal | Ignition switch ON (IG) | Pulse generation (Waveform 1) |
| A33-5 (CLK+) - A33-28 (GND1) | B - W-B | MG ECU communication clock signal | Ignition switch ON (READY) | Pulse generation (Waveform 2) |
| A33-6 (REQ+) - A33-28 (GND1) | B - W-B | MG ECU communication request signal | Ignition switch ON (READY) | Pulse generation (Waveform 3) |
| A33-7 (MTH+) - A33-28 (GND1) | B - W-B | Communication signal from MG ECU to power management control ECU | Ignition switch ON (READY) | Pulse generation (Waveform 4) |
| A33-8 (HTM+) - A33-28 (GND1) | B - W-B | Communication signal from power management control ECU to MG ECU | Ignition switch ON (READY) | Pulse generation (Waveform 5) |
| A33-9 (+B2) - A33-28 (GND1) | G - W-B | MG ECU power source | Ignition switch ON (IG) | 11 to 14 V |
| A33-10 (+B) - A33-28 (GND1) | G - W-B | MG ECU power source | Ignition switch ON (IG) | 11 to 14 V |
| A33-12 (NODD) - A33-28 (GND1) | W - W-B | DC/DC operation | DC/DC converter operating normally | 5 to 7 V |
| DC/DC converter not operating normally | 2 to 4 V | |||
| DC/DC converter operation prohibited | 0.1 to 0.5 V | |||
| A33-15 (CLK-) - A33-28 (GND1) | W - W-B | MG ECU communication clock signal | Ignition switch ON (READY) | Pulse generation (Waveform 2) |
| A33-16 (REQ-) - A33-28 (GND1) | W - W-B | MG ECU communication request signal | Ignition switch ON (READY) | Pulse generation (Waveform 3) |
| A33-17 (MTH-) - A33-28 (GND1) | W - W-B | Communication signal from MG ECU to power management control ECU | Ignition switch ON (READY) | Pulse generation (Waveform 4) |
| A33-18 (HTM-) - A33-28 (GND1) | W - W-B | Communication signal from power management control ECU to MG ECU | Ignition switch ON (READY) | Pulse generation (Waveform 5) |
| A33-29 (GI) - A33-28 (GND1) | B - W-B | Camshaft position sensor signal | Ignition switch ON (READY), with engine running | Pulse generation (Waveform 6) |
| A33-31 (HSDN) - A33-28 (GND1) | B - W-B | MG shutdown signal | Ignition switch ON (READY) | 0 to 1 V |
| A33-35 (ILKI) - A33-28 (GND1) | V - W-B | Interlock switch signal | Ignition switch ON (IG), inverter terminal cover, frame wire connector (to inverter with converter assembly) and service plug grip installed correctly | Below 1 V |
| Ignition switch ON (IG), inverter terminal cover, frame wire connector (to inverter with converter assembly) or service plug grip not installed | 11 to 14 | |||
| A33-36 (ILKO) - A33-28 (GND1) | LG - W-B | Interlock switch signal | Ignition switch ON (IG), inverter terminal cover, frame wire connector (to inverter with converter assembly) and service plug grip installed correctly | Below 1 V |
| Ignition switch ON (IG), inverter terminal cover, frame wire connector (to inverter with converter assembly) or service plug grip not installed | 11 to 14 | |||
| C28-1 (MRF) - C28-2 (MRFG) | BR - G | Motor resolver signal | Motor resolver running | Pulse generation (Waveform 7) |
| C28-3 (MSN) - C28-4 (MSNG) | L - R | Motor resolver signal | Motor resolver running | Pulse generation (Waveform 7) |
| C28-6 (MCS) - C28-5 (MCSG) | W - Y | Motor resolver signal | Motor resolver running | Pulse generation (Waveform 7) |
| C28-7 (GSN) - C28-8 (GSNG) | L - R | Generator resolver signal | Generator resolver running | Pulse generation (Waveform 8) |
| C28-10 (GCS) - C28-9 (GCSG) | W - Y | Generator resolver signal | Generator resolver running | Pulse generation (Waveform 8) |
| C28-11 (GRF) - C28-12 (GRFG) | BR - G | Generator resolver signal | Generator resolver running | Pulse generation (Waveform 8) |
Note
Do not measure the voltage or waveform directly at the sealed side of the inverter with converter assembly connector. Doing so may damage the connector because the connector is waterproof.
Oscilloscope waveforms
Tech Tips
Oscilloscope waveform samples are provided here for informational purposes. Noise and fluttering waveforms have been omitted.
Waveform 1 (DC/DC operation monitor / voltage change signal)
| Item | Content |
|---|---|
| Terminal | A33-3 (VLO) - A33-28 (GND1) |
| Equipment Setting | 5 V/DIV., 50 ms./DIV. |
| Condition | Ignition switch ON (IG) |
Tech Tips
The cycle will vary depending on the specified voltage of the hybrid vehicle converter.
Waveform 2 (MG ECU communication clock signal)(Reference)
| Item | Content |
|---|---|
| Terminal | CH1: A33-5 (CLK+) - A33-28 (GND1) CH2: A33-15 (CLK-) - A33-28 (GND1) |
| Equipment Setting | 1 V/DIV., 1 μs./DIV. |
| Condition | Ignition switch ON (READY) |
Waveform 3 (MG ECU communication request signal)
| Item | Content |
|---|---|
| Terminal | CH1: A33-6 (REQ+) - A33-28 (GND1) CH2: A33-16 (REQ-) - A33-28 (GND1) |
| Equipment Setting | 1 V/DIV., 1 ms./DIV. |
| Condition | Ignition switch ON (READY) |
Waveform 4 (communication signal from MG ECU to power management control ECU)
| Item | Content |
|---|---|
| Terminal | CH1: A33-7 (MTH+) - A33-28 (GND1) CH2: A33-17 (MTH-) - A33-28 (GND1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Ignition switch ON (READY) |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 5 (communication signal from power management control ECU to MG ECU)
| Item | Content |
|---|---|
| Terminal | CH1: A33-8 (HTM+) - A33-28 (GND1) CH2: A33-18 (HTM-) - A33-28 (GND1) |
| Equipment Setting | 1 V/DIV., 200 μs./DIV. |
| Condition | Ignition switch ON (READY) |
Tech Tips
The waveform will vary depending on the content of the digital communication (digital signal).
Waveform 6 (camshaft position sensor signal)
| Item | Content |
|---|---|
| Terminal | A33-29 (GI) - A33-28 (GND1) |
| Equipment Setting | 5 V/DIV., 20 ms./DIV. |
| Condition | Ignition switch ON (READY), with engine running |
Tech Tips
The pulse cycle becomes shorter as the engine speed increases.
Waveform 7 (motor resolver signal)
| Item | Content |
|---|---|
| Terminal | CH1: C28-1 (MRF) - C28-2 (MRFG) CH2: C28-3 (MSN) - C28-4 (MSNG) CH3: C28-6 (MCS) - C28-5 (MCSG) |
| Equipment Setting | CH1: 10 V/DIV., 1 ms./DIV. CH2, 3: 5 V/DIV., 1 ms./DIV. |
| Condition | Motor resolver running |
Tech Tips
Pulse cycle A becomes shorter as the rotor speed increases.
Waveform 8 (generator resolver signal)
| Item | Content |
|---|---|
| Terminal | CH1: C28-11 (GRF) - C28-12 (GRFG) CH2: C28-7 (GSN) - C28-8 (GSNG) CH3: C28-10 (GCS) - C28-9 (GCSG) |
| Equipment Setting | CH1: 10 V/DIV., 1 ms./DIV. CH2, 3: 5 V/DIV., 1 ms./DIV. |
| Condition | Generator resolver running |
Tech Tips
Pulse cycle A becomes shorter as the rotor speed increases.