HYBRID / BATTERY CONTROL SERVICE DATA

Coolant (for Inverter)
Reserve Tank Cap (for Inverter)
Standard value for brand-new cap

94 to 122 kPa (1.0 to 1.2 kgf/cm2, 13.6 to 18 psi)

Minimum standard value for used cap

94 kPa (1.0 kgf/cm2, 13.6 psi)

Relay
IGCT relay
Standard resistance 3 - 5 10 kΩ or higher (when battery voltage is not applied across terminals 1 and 2)
Below 1 Ω (when battery voltage is applied across terminals 1 and 2)
Hybrid relay assembly
Hybrid Battery Junction Block

SMRB

Standard resistance

(+) - (CBI)

10 kΩ or higher

(Battery voltage is not applied between terminals 1 (SMRB) and 2 (GND))

Below 1 Ω

(Battery voltage is applied between terminals 1 (SMRB) and 2 (GND))

1 (SMRB) - 2 (GND) 25.0 to 59.0 Ω (at -40 to 80°C (-40 to 176°F))

SMRG

Standard resistance

(-) - (CEI)

10 kΩ or higher

(Auxiliary battery voltage is not applied between terminals 3 (SMRG) and (GND))

Below 1 Ω

(Battery voltage is applied between terminals 3 (SMRG) and 2 (GND))

3 (SMRG) - 2 (GND) 25.0 to 59.0 Ω (at -40 to 80°C (-40 to 176°F))

SMRP

Standard resistance

(CEI) - (-)

10 kΩ or higher

(Battery voltage is not applied between terminals 4 (SMRP) and 2 (GND))

28.5 to 31.5 Ω

(Battery voltage is applied between terminals 4 (SMRP) and 2 (GND))

4 (SMRP) - 2 (GND) 112 to 274 Ω (at -40 to 80°C (-40 to 176°F))
Combination switch
EV drive mode switch (Pattern select switch assembly)
Standard resistance 4 (S) - 1 (E) Below 1 Ω(when EV drive mode switch being pushed and held)
10 kΩ or higher (when EV drive mode switch not pushed)
Illumination Battery positive (+) → 3 (ILL+) Battery negative (-) → 2 (ILL-) Illuminates
Service plug grip
Service plug grip
Standard resistance - Below 1 Ω