DESCRIPTION
The main body ECU (multiplex network body ECU) controls the operation of the TAIL relay.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body / Active Test.
Check that the relay operates.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Taillight Relay | Taillight relay | ON/OFF | - |
| OK |
|---|
| Taillight relay operates. (Taillights illuminate.) |
| NG |
|
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY Click here |
| OK |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY
| *1 | Component without harness connected (Instrument Panel Junction Block Assembly) |
Remove the instrument panel junction block assembly.
Connect a positive (+) lead from the battery to terminal 2K-1.
Connect a negative (-) lead from the battery to terminal A-14.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY |
| OK |
|
CHECK HARNESS AND CONNECTOR (BATTERY - INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY)
| *1 | Front view of wire harness connector (to Instrument Panel Junction Block Assembly) |
Disconnect the 2K instrument panel junction block assembly connector.
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE MAIN BODY ECU (MULTIPLEX NETWORK BODY ECU) Click here