FUEL LID OPENER MOTOR ASSEMBLY INSPECTION


  1. INSPECT FUEL FILLER OPENING LID LOCK SUB-ASSEMBLY


    1. A01ND4NE02

      Apply auxiliary battery voltage to the motor terminals and check that the motor operates and the shaft moves in the open direction.

      OK
      Measurement Condition Specified Condition

      Auxiliary battery positive (+) → Terminal 2

      Auxiliary battery negative (-) → Terminal 1

      Motor operates and shaft moves in open direction
    2. Measure the shaft stroke.

      Standard
      10.3 mm (0.406 in.) or more

      If the result is not as specified, replace the motor assembly.