Measure the resistance according to the value(s) in the table below.
if the result is not as specified, replace the switch.
| Standard Resistance (Slide Switch) |
| Tester Connection |
Switch Condition |
Specified Condition |
| 1 (B) - 9 (SLDF) |
FRONT |
Below 1 Ω |
| 4 (E) - 6 (SLDR) |
FRONT |
Below 1 Ω |
| 4 (E) - 6 (SLDR) |
OFF |
Below 1 Ω |
| 4 (E) - 9 (SLDF) |
OFF |
Below 1 Ω |
| 1 (B) - 6 (SLDR) |
REAR |
Below 1 Ω |
| 4 (E) - 9 (SLDF) |
REAR |
Below 1 Ω |
|
| Standard Resistance (Front Vertical Switch) |
| Tester Connection |
Switch Condition |
Specified Condition |
| 1 (B) - 5 (FUP) |
UP |
Below 1 Ω |
| 4 (E) - 10 (FDWN) |
UP |
Below 1 Ω |
| 4 (E) - 5 (FUP) |
OFF |
Below 1 Ω |
| 4 (E) - 10 (FDWN) |
OFF |
Below 1 Ω |
| 1 (B) - 10 (FDWN) |
DOWN |
Below 1 Ω |
| 4 (E) - 5 (FUP) |
DOWN |
Below 1 Ω |
|
| Standard Resistance (Lifter Switch) |
| Tester Connection |
Switch Condition |
Specified Condition |
| 1 (B) - 8 (LUP) |
UP |
Below 1 Ω |
| 4 (E) - 7 (LDWN) |
UP |
Below 1 Ω |
| 4 (E) - 8 (LUP) |
OFF |
Below 1 Ω |
| 4 (E) - 7 (LDWN) |
OFF |
Below 1 Ω |
| 1 (B) - 7 (LDWN) |
DOWN |
Below 1 Ω |
| 4 (E) - 8 (LUP) |
DOWN |
Below 1 Ω |
|
| Standard Resistance (Reclining Switch) |
| Tester Connection |
Switch Condition |
Specified Condition |
| 1 (B) - 3 (RCLF) |
UP |
Below 1 Ω |
| 4 (E) - 2 (RCLR) |
UP |
Below 1 Ω |
| 4 (E) - 2 (RCLR) |
OFF |
Below 1 Ω |
| 4 (E) - 3 (RCLF) |
OFF |
Below 1 Ω |
| 1 (B) - 2 (RCLR) |
DOWN |
Below 1 Ω |
| 4 (E) - 3 (RCLF) |
DOWN |
Below 1 Ω |
|
If the result is not as specified, replace the switch.