COMBINATION METER INSTALLATION


  1. INSTALL COMBINATION METER ASSEMBLY


    1. Connect each connector.

    2. A01NCTD

      Install the combination meter assembly with the 2 screws.

  2. INSTALL NO. 1 INSTRUMENT CLUSTER FINISH PANEL


    1. A01NGA6

      Engage the 4 clips and 2 guides.

    2. Install the No. 1 instrument cluster finish panel with the 2 clips and 2 screws.

  3. INSTALL NO. 2 INSTRUMENT PANEL HOLE COVER

    Tech Tips

    Use the same procedure as for the No. 1 instrument panel hole cover.

  4. INSTALL NO. 1 INSTRUMENT PANEL HOLE COVER


    1. A01NDP1

      Engage the 2 claws to install the No. 1 instrument panel hole cover.

  5. INSTALL LOWER INSTRUMENT PANEL FINISH PANEL SUB-ASSEMBLY


    1. Connect each connector.

    2. A01NG78

      Engage the 8 clips and 2 guides.

    3. Install the lower instrument panel finish panel sub-assembly with the 2 screws <D>.

    4. A01NE1K

      Engage the 2 claws to close the cover as shown in the illustration.

  6. INSTALL NO. 1 SWITCH HOLE BASE


    1. Connect each connector.

    2. A01NFF7

      Engage the 4 claws and 2 guides to install the No. 1 switch hole base.

  7. INSTALL INSTRUMENT PANEL GARNISH LH


    1. A01NH3A

      Engage the 6 clips to install the instrument panel garnish LH.

  8. CONNECT CABLE TO NEGATIVE BATTERY TERMINAL

    Note


    • Make sure that the cable has been disconnected from the negative (-) battery terminal for at least 2 seconds before reconnecting the cable.

    • Reset the auto tilt away function setting to the previous condition by changing the customize parameter Click here.

    • When disconnecting the cable, some systems need to be initialized after the cable is reconnected Click here.

  9. INSTALL REAR DECK FLOOR BOX


    1. A01NDSY

      Install the rear deck floor box with the 3 clips.

  10. INSPECT SUSPENSION CONTROL SYSTEM (w/ Air Suspension)


    1. Inspect the suspension control system Click here.