METER / GAUGE SYSTEM Entire Combination Meter does not Operate

DESCRIPTION

This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ in turning the power switch on (IG), the indicator will not operate.

WIRING DIAGRAM

A01NHK1E01

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT COMBINATION METER ASSEMBLY


    1. A01NHX7E02
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Combination Meter Assembly)

      *2

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Disconnect the F15 and F16 connectors.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F15-16 (E2) - Body ground Always Below 1 Ω
      F16-6 (ES) - Body ground Always Below 1 Ω
    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F16-1 (IG+) - Body ground Power switch on (IG) 11 to 14 V
      F16-13 (B) - Body ground Power switch off 11 to 14 V

    NG
    OK