DESCRIPTION
This circuit is the power source circuit for the meter. This circuit provides two types of power sources; one is a constant power source mainly used as a backup power source, and the other is an IG power source mainly used for signal transmission. The constant power source is mainly used as a backup power source for the meter CPU, however, it is also used for CAN communication. If a voltage of 12 V is not applied to terminal IG+ in turning the power switch on (IG), the indicator will not operate.
WIRING DIAGRAM
INSPECTION PROCEDURE
PROCEDURE
INSPECT COMBINATION METER ASSEMBLY
| *1 | Front view of wire harness connector (to Combination Meter Assembly) |
| *2 | Front view of wire harness connector (to Combination Meter Assembly) |
Disconnect the F15 and F16 connectors.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
REPLACE COMBINATION METER ASSEMBLY Click here