ENTRY AND START SYSTEM (for Start Function) Power Source Mode does not Change to ON (ACC)

DESCRIPTION

When the power switch is pushed with the electrical key in the cabin, the power management control ECU receives signals to change the power source mode.

Tech Tips

To allow use of the intelligent tester to inspect the push-button start function when the power source mode is off, repeat opening and closing any of the doors. Opening and closing a door establishes communication between the intelligent tester and power management control ECU. (Opening and closing a door can also be simulated by operating a door courtesy light switch.)

WIRING DIAGRAM

Refer to DTC B2274 Click here.

INSPECTION PROCEDURE

PROCEDURE


  1. CHECK HARNESS OR CONNECTOR (AUXILIARY BATTERY - POWER MANAGEMENT CONTROL ECU)


    1. A01NHLTE03
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Power Management Control ECU)

      Disconnect the F97 and F98 connectors from the power management control ECU.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F97-1 (AM22) - Body ground Always 9.5 to 16 V
      F98-7 (AM21) - Body ground Always 9.5 to 16 V

    NG
    OK
  2. CHECK HARNESS OR CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)


    1. A01NHLTE04
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F97-5 (E01) - Body ground Always Below 1 Ω
      F97-6 (E1) - Body ground Always Below 1 Ω
      F98-4 (E12) - Body ground Always Below 1 Ω
      F98-5 (E02) - Body ground Always Below 1 Ω

    NG
    OK
  3. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY


    1. A01NERXE02
      Text in Illustration
      *1

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      Remove the instrument panel junction block assembly Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2A-3 - 2A-17 20°C (68°F) 81.49 to 118.98 Ω

    NG
    OK
  4. CHECK HARNESS AND CONNECTOR


    1. A01NGGGE01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F98-1 (ACCD) - 2A-17 Always Below 1 Ω
      F98-1 (ACCD) - Body ground Always 10 kΩ or higher

    NG
    OK
  5. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)


    1. A01NGB6E02
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      Measure the resistance according to the value(s) the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2A-3 - Body ground Always Below 1 Ω

    NG
    OK
  6. INSPECT POWER MANAGEMENT CONTROL ECU


    1. A01NFAQE02
      Text in Illustration
      *1

      Component with harness connected

      (Power Management Control ECU)

      Reinstall the instrument panel junction block assembly Click here.

    2. Reconnect the F98 connector.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F98-1 (ACCD) - Body ground Power switch on (ACC) Output voltage at terminal AM21 or AM22 -2.5 V or more
    4. Proceed to the next step based on the inspection result.

      Result
      Result Proceed to
      OK A
      NG (for LHD) B
      NG (for RHD) C

    B
    C
    A