ENTRY AND START SYSTEM (for Start Function), Diagnostic DTC:B2271

DTC Code DTC Name
B2271 Ignition Hold Monitor Malfunction

DESCRIPTION

This DTC is stored when a problem such as an open in the AM2 fuse, an open or short in the wire harness between the fuse and power management control ECU, a short in the IG output circuit inside the power management control ECU, a short between the power management control ECU and relay, or a short in the relay is detected.

DTC No. DTC Detection Condition Trouble Area
B2271 The hold circuit, IG1 relay actuation circuit or IG2 relay actuation circuit inside the power management control ECU is open or shorted.
  • AM2 fuse

  • IG1 relay

  • IG2 relay

  • Power management control ECU

  • Instrument panel junction block assembly

  • Wire harness or connector

WIRING DIAGRAM

A01ND70E02

INSPECTION PROCEDURE

Note


  • When the power management control ECU is replaced with a new one and the cable from the negative (-) auxiliary battery terminal is connected, the power source mode becomes on (IG) mode. When the auxiliary battery is removed and reinstalled, the power source mode that was selected when the auxiliary battery was removed is restored.

  • Inspect the fuses for circuits related to this system before performing the following inspection procedure.

PROCEDURE


  1. CHECK HARNESS AND CONNECTOR (AUXILIARY BATTERY - POWER MANAGEMENT CONTROL ECU)


    1. A01NHLTE03
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Power Management Control ECU)

      Disconnect the F97 and F98 connectors from the power management control ECU.

    2. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      F97-1 (AM22) - Body ground Always 9.5 to 16 V
      F98-7 (AM21) - Body ground Always 9.5 to 16 V

    NG
    OK
  2. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - BODY GROUND)


    1. A01NHLTE04
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Power Management Control ECU)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F97-5 (E01) - Body ground Always Below 1 Ω
      F97-6 (E1) - Body ground Always Below 1 Ω
      F98-4 (E12) - Body ground Always Below 1 Ω
      F98-5 (E02) - Body ground Always Below 1 Ω

    NG
    OK
  3. INSPECT IG1 RELAY


    1. A01ND26

      Remove the IG1 relay from the engine room relay block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 130 to 230 Ω
      3 - 5 When auxiliary battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When auxiliary battery voltage is applied to terminals 1 and 2 Below 1 Ω

    NG
    OK
  4. INSPECT IG2 RELAY


    1. A01ND26

      Remove the IG2 relay from the engine room relay block assembly.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      1 - 2 Always 130 to 230 Ω
      3 - 5 When auxiliary battery voltage is not applied to terminals 1 and 2 10 kΩ or higher
      3 - 5 When auxiliary battery voltage is applied to terminals 1 and 2 Below 1 Ω

    NG
    OK
  5. INSPECT INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY (IG NO. 1, IG NO. 2 AND IG NO. 3 RELAY)


    1. A01NERXE01
      Text in Illustration
      *1

      Component without harness connected

      (Instrument Panel Junction Block Assembly)

      Remove the instrument panel junction block assembly Click here.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2A-20 - 2A-3 20°C (68°F) 52.32 to 79.32 Ω

    NG
    OK
  6. CHECK HARNESS AND CONNECTOR


    1. A01ND4GE01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Management Control ECU)

      *2

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      F98-2 (IG1D) - 2A-20 Always Below 1 Ω
      F98-2 (IG1D) - Body ground Always 10 kΩ or higher

    NG
    OK
  7. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - BODY GROUND)


    1. A01NGB6E01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2A-3 - Body ground Always Below 1 Ω

    NG
    OK
  8. CHECK HARNESS AND CONNECTOR (INSTRUMENT PANEL JUNCTION BLOCK ASSEMBLY - IG1 RELAY)


    1. A01NG5RE02
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Instrument Panel Junction Block Assembly)

      *2

      Component without relay connected

      (Engine Room Relay Block Assembly)

      *3 IG1 Relay Terminal

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2F-14 - Engine room relay block IG1 relay terminal 1 Always Below 1 Ω
      2F-14 - Body ground Always 10 kΩ or higher

    NG
    OK
  9. CHECK HARNESS AND CONNECTOR (POWER MANAGEMENT CONTROL ECU - IG2 RELAY)


    1. A01NEC8E01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Power Management Control ECU)

      *2

      Component without relay connected

      (Engine Room Relay Block Assembly)

      *3 IG2 Relay Terminal

      Disconnect the A81 connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      A81-2 (IG2D) - Engine room relay block IG2 relay terminal 1 Always Below 1 Ω
      A81-2 (IG2D) - Body ground Always 10 kΩ or higher

    NG
    OK
  10. CHECK HARNESS AND CONNECTOR (ENGINE ROOM RELAY BLOCK ASSEMBLY - BODY GROUND)


    1. A01NFR4E01
      Text in Illustration
      *1

      Component without harness connected

      (Engine Room Relay Block Assembly)

      *2 IG2 Relay Terminal
      *3 IG1 Relay Terminal

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      Engine room relay block IG1 relay terminal 2 - Body ground Always Below 1 Ω
      Engine room relay block IG2 relay terminal 2 - Body ground Always Below 1 Ω

    NG
    OK
  11. CHECK POWER MANAGEMENT CONTROL ECU


    1. A01NFAQE01
      Text in Illustration
      *1

      Component with harness connected

      (Power Management Control ECU)

      Install the instrument panel junction block assembly Click here.

    2. Reconnect the A81 and F98 connectors.

    3. Measure the voltage according to the value(s) in the table below.

      Standard Voltage
      Tester Connection Condition Specified Condition
      A81-2 (IG2D) - Body ground Power switch on (IG) Output voltage at terminal AM21 or AM22 -2.5 V or more
      F98-2 (IG1D) - Body ground Power switch on (IG) Output voltage at terminal AM21 or AM22 -2.5 V or more
    4. Proceed to the next step based on the inspection result.

      Result
      Result Proceed to
      OK A
      NG (for LHD) B
      NG (for RHD) C

    B
    C
    A