CUSTOMIZING FUNCTION WITH INTELLIGENT TESTER
Tech Tips
The following items can be customized.
Note
When the customer requests a change in a function, first make sure that the function can be customized.
Be sure to make a note of the current settings before customizing.
When troubleshooting a function, first make sure that the function is set to the default setting.
CUSTOMIZE
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Main Body or Illuminated Entry / Utility / Customize.
Select the setting by referring to the table below.
| Display (item) | Default | Function | Setting |
|---|---|---|---|
| Wireless Control | ON | Function that turns wireless door lock / ON or OFF | ON or OFF |
| Hazard Answer Back | ON | When the doors are locked by wireless operation, the hazard warning lights flash once. When the doors are unlocked by wireless operation, the hazard warning lights flash twice. |
ON or OFF |
| Open Door Warning*1 | ON | The buzzer sounds when lock is pressed when any of the doors are ajar. | ON or OFF |
| Unlock 2 Operation | ON*2 or OFF*3 | Function that unlocks driver door when unlock switch on transmitter is pressed once, and unlocks all doors when pressed twice. If setting is OFF, pressing unlock switch once makes all doors unlock. | ON or OFF |
| Panic Function*4 | ON | Function to operate theft deterrent system by continuously pressing panic switch on transmitter for 0.8 seconds | ON or OFF |
| Auto Lock Time | 30 s | Function that regulates the interval between unlocking and automatic relocking of doors | 30 s, 60 s or 120 s |
| Wireless Buzzer Resp*5 | ON | Wireless door lock buzzer response / ON or OFF | ON or OFF |
| P/W Wireless Ope Buzz*6 | ON | Wireless power window buzzer response / ON or OFF | ON or OFF |
| Wireless Buzzer Vol*1 | Level7 | Wireless door lock buzzer Volume | Level7, Level6, Level5, Level4, Level3, Level2, Level1 or Level0 |
*1: w/ Door ajar warning function
*2: for GCC and Australia
*3: except for GCC and Australia
*4: w/ Panic function
*5: w/ Wireless buzzer answer back function
*6: w/ Wireless power window buzzer response function
| Display | Default | Content | Setting |
|---|---|---|---|
| Lighting Time | 15 s | Changes the lighting time after closing all doors. (It will quickly fade out in case of turning the power switch from off to on (ACC or IG).) | 7.5 s, 15 s or 30 s |