INSPECT INTEGRATION RELAY
Inner circuit
for A/F relay
| *1 | Component without harness connected (Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the result is not as specified, replace the integration relay.
for S-HORN relay
| *1 | Component without harness connected (Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the result is not as specified, replace the integration relay.
for HORN relay
| *1 | Component without harness connected (Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the result is not as specified, replace the integration relay.
for HEAD (RL) relay
| *1 | Component without harness connected (Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the result is not as specified, replace the integration relay.
for HEAD (LL) relay
| *1 | Component without harness connected (Integration Relay) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the result is not as specified, replace the integration relay.
for HEAD HI relay
| *1 | Component without harness connected (Integration Relay) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
Tech Tips
If the result is not as specified, replace the integration relay.