G-BOOK SYSTEM TERMINALS OF ECU


  1. TELEMATICS TRANSCEIVER

    A01NE8EE02
    Terminal No. (Symbol) Wiring Color Terminal Description Condition Specified Condition
    G25-1 (+B) - G25-4 (E) W - W-B Battery Power switch off 11 to 14 V
    G25-2 (SPI+) - G25-4 (E) R - W-B Sound signal Audio system playing A waveform synchronized with sounds is output.
    G25-3 (SPI-) - G25-4 (E) P - W-B Sound signal Audio system playing A waveform synchronized with sounds is output.
    G25-4 (E) - Body ground W-B - Body ground Ground Always Below 1 V
    G25-5 (SPO+) - G25-4 (E) G - W-B Sound signal Emergency call mode A waveform synchronized with the received voice is output.
    G25-6 (SPO-) - G25-4 (E) R - W-B Sound signal Emergency call mode A waveform synchronized with the received voice is output.
    G25-7 (IG2) - G25-4 (E) W - W-B Power source (IG) Power switch on (IG) 11 to 14 V
    Power switch off Below 1 V
    G25-8 (ACC) - G25-4 (E) Y - W-B Accessory (ON) Power switch on (ACC) 11 to 14 V
    Power switch off Below 1 V
    G25-9 (SLED) - G25-4 (E) GR - W-B Telephone switch assembly illumination power supply Power switch on (ACC) 5 to 8 V
    Power switch off Below 1 V
    G25-11 (IND1) - G25-4 (E) V - W-B Telephone switch assembly red indicator illumination signal For 5 seconds after turning the power switch on (ACC) 1 to 8.5 V
    Power switch off Below 1 V
    G25-12 (IND2) - G25-4 (E) BR - W-B Telephone switch assembly green indicator illumination signal For 5 seconds after turning the power switch on (ACC) 1 to 8.5 V
    Power switch off Below 1 V
    G25-13 (BBI-) - G25-4 (E) L - W-B Mayday battery power supply - -
    G25-17 (MUTE) - G25-4 (E) LG - W-B MUTE Signal Audio system playing Below 1 V
    Emergency call mode 3.5 V or higher
    G25-18 (MCO+) - G25-4 (E) G - W-B Microphone voice signal

    See "Microphone&Voice Recognition Check" Click here

    -
    G25-19 (MCO-) - G25-4 (E) R - W-B Microphone voice signal

    See "Microphone&Voice Recognition Check" Click here

    -
    G25-20 (CTR1) - G25-4 (E) B - W-B Mayday battery control line - -
    G25-21 (CTR2) - G25-4 (E) Y - W-B Mayday battery control line - -
    G25-24 (GSW) - G25-4 (E) R - W-B Airbag deployment signal Power switch on (IG)

    Pulse generation

    (Refer to waveform 1)

    G25-26 (SIG-) - G25-4 (E) G - W-B Ground Always Below 1 V
    G25-27 (SIG1) - G25-26 (SIG-) Y - G Telephone switch assembly button condition signal Telephone switch assembly button not pressed 1.7 V
    Telephone switch assembly button pressed 0.7 V
    G25-30 (BBI+) - G25-4 (E) R - W-B Mayday Battery Power Supply - -
    G25-32 (SGND) - G25-4 (E) W-B - Body ground Shield ground Always Below 1 V
    G25-33 (MCVD) - G25-4 (E) B - W-B Telephone microphone assembly power supply Power switch on (ACC) 4 to 6 V
    Power switch off Below 1 V
    G25-34 (MCI+) - G25-4 (E) W - W-B Microphone voice signal

    See "Microphone&Voice Recognition Check" Click here

    -
    G25-35 (MCI-) - G25-4 (E) R - W-B Microphone voice signal

    See "Microphone&Voice Recognition Check" Click here

    -
    G34-1-1 (USB-) B USB communication line - -
    G34-1-2 (USB+) B USB communication line - -
    G34-1-3 (USBG) B - Body ground Shield ground Always Below 1 V
    G34-2 (USBG) - Body ground W - Body ground Shield ground Always Below 1 V
    G34-3 (VOT+) - G25-4 (E) B - W-B Receive voice signal Receiving a call while using the operator service A waveform synchronized with the received voice is output.
    G34-4 (USBV) - G25-4 (E) W - W-B Telematics transceiver power supply Power switch on (ACC) 4.5 to 5.25 V
    Power switch off Below 1 V
    G34-5 (VOT-) - G25-4 (E) B - W-B Receive voice signal Receiving a call while using the operator service A waveform synchronized with the received voice is output.
    G34-6 (VOR-) - G25-4 (E) B - W-B Sent voice signal Calling while using the operator service A waveform synchronized with the sent voice is output
    G34-7 (VOR+) - G25-4 (E) B - W-B Sent voice signal Calling while using the operator service A waveform synchronized with the sent voice is output

    1. Reference (Oscilloscope waveform):


      1. A01NE4XE01

        Waveform 1

        Item Condition
        Tester Connection G25-24 (GSW) - G25-4 (E)
        Tool setting 5.0 V/DIV., 20 ms/DIV.
        Vehicle condition Power switch on (IG)
  2. DISPLAY AND NAVIGATION MODULE DISPLAY Click here