SMOG VENTILATION SENSOR INSPECTION


  1. INSPECT SMOG VENTILATION SENSOR


    1. A01NGPBE15
      Text in Illustration
      *1

      Component without harness connected

      (Smog Ventilation Sensor)

      HC, CO


      1. Connect a battery positive (+) lead to terminal 3 (IG) and a negative (-) lead to terminal 6 (E).

      2. Allow exhaust gas (HC, CO) to travel to the sensing portion of the smog ventilation sensor, and measure the resistance between terminals 1 (SG) and 2 (DGS).

        OK
        When the sensor is exposed to the exhaust gas, the resistance increases.

        Tech Tips

        The resistance before blowing exhaust gas is 10 kΩ to 40 kΩ.

        If the result is not as specified, replace the smog ventilation sensor.

    2. A01NGPBE21
      Text in Illustration
      *1

      Component without harness connected

      (Smog Ventilation Sensor)

      NOx


      1. Connect a battery positive (+) lead to terminal 3 (IG) and a negative (-) lead to terminal 6 (E).

      2. Allow exhaust gas (NOx) to travel to the sensing portion of the smog ventilation sensor, and measure the resistance between terminals 1 (SG) and 4 (DGS1).

        OK
        When the sensor is exposed to the exhaust gas, the resistance increases.

        Tech Tips

        The resistance before blowing exhaust gas is 10 kΩ to 40 kΩ.

        If the result is not as specified, replace the smog ventilation sensor.