DESCRIPTION
The blower motor is operated by signals from the A/C amplifier. Blower motor speed signals are transmitted in accordance with changes in the duty ratio.
WIRING DIAGRAM
INSPECTION PROCEDURE
Note
Inspect the fuses for circuits related to this system before performing the following inspection procedure.
PROCEDURE
PERFORM ACTIVE TEST USING INTELLIGENT TESTER
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| OK |
|---|
| Blower motor operates and blower motor speed level changes. |
| Result | ||||||||
|---|---|---|---|---|---|---|---|---|
|
| B |
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND) Click here |
| C |
|
INSPECT A/C AMPLIFIER Click here |
| A |
|
PROCEED TO NEXT SUSPECTED AREA SHOWN IN PROBLEM SYMPTOMS TABLE Click here
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BODY GROUND)
| *1 | Front view of wire harness connector (to Blower Motor) |
Disconnect the blower motor connector.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - BATTERY)
| *1 | Front view of wire harness connector (to Blower Motor) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK HARNESS AND CONNECTOR (BLOWER MOTOR - A/C AMPLIFIER)
Disconnect the A/C amplifier connector.
| *1 | Front view of wire harness connector (to A/C Amplifier) |
| *2 | Front view of wire harness connector (to Blower Motor) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | |||||||||
|---|---|---|---|---|---|---|---|---|---|
|
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
INSPECT BLOWER MOTOR
Reconnect the blower motor connector.
| *1 | Front view of wire harness connector (to A/C Amplifier) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
| NG |
|
REPLACE BLOWER MOTOR Click here |
| OK |
|
INSPECT A/C AMPLIFIER
| *1 | Component with harness connected (A/C Amplifier) |
Remove the A/C amplifier.
Reconnect the A/C amplifier connector.
Turn the power switch on (IG).
Set the blower speed to low.
Measure the waveform between terminal F50-23 (BLW) of the A/C amplifier and body ground.
| Item | Content |
|---|---|
| Tool setting | 1 V/DIV., 500 μs/DIV. |
| Vehicle condition | Power switch on (IG) Blower set to low |
| OK |
|---|
| Waveform is as shown in the illustration. |
Tech Tips
The waveform varies with the blower speed.
| NG |
|
REPLACE A/C AMPLIFIER Click here |
| OK |
|
REPLACE BLOWER MOTOR Click here