AIR CONDITIONING SYSTEM, Diagnostic DTC:B1476/76

DTC Code DTC Name
B1476/76 A/C Inverter Load System Malfunction

DESCRIPTION

The compressor with motor assembly stops compressor control and outputs this DTC if the rotation load is too large or too small while controlling motor rotation in the compressor with motor assembly.

Possible causes are refrigerant gas leakage, overcharged refrigerant gas, insufficient cooling because of a condenser fan circuit malfunction, or compressor lock.

DTC No. DTC Detection Condition Trouble Area
B1476/76 Motor rotation load while the compressor is operating is too large or too small.
  • Refrigerant volume


  • Compressor with motor assembly


  • Cooling fan system

  • CAN communication system

INSPECTION PROCEDURE

CAUTION:


  • Wear electrically insulated gloves and pull out the service plug grip before inspection as procedures may require disconnecting high-voltage connectors. Be sure to carry the removed service plug grip because other workers may install it by mistake.

  • Do not touch the high-voltage connectors or terminals for 10 minutes after the service plug grip is removed.

Note

The hybrid control system and air conditioning system output DTCs separately. Inspect DTCs following the flow chart for the hybrid control system first if any DTCs from those systems are output simultaneously.

PROCEDURE


  1. CHECK CAN COMMUNICATION SYSTEM


    1. Using the intelligent tester to check if the CAN communication system is functioning normally.

      Result
      Result Proceed to
      CAN DTC is not output A
      CAN DTC is output B

    B
    A
  2. PERFORM ACTIVE TEST USING INTELLIGENT TESTER


    1. Connect the intelligent tester to the DLC3.

    2. Turn the power switch on (IG).

    3. Turn the intelligent tester on.

    4. Enter the following menus: Powertrain / Engine / Active Test.

    5. Check the operation by referring to the table below.

      Engine
      Tester Display Test Part Control Range Diagnostic Note
      Control the Electric Cooling Fan Electrical fan OFF, ON -
      OK
      Electrical fan operates smoothly.

    NG
    OK
  3. CHECK REFRIGERANT PRESSURE


    1. Install the manifold gauge set Click here.

    2. A01NESW

      Read the manifold gauge pressure when the following conditions are established.


      1. Prepare the vehicle according to the chart below.

        Item Condition
        Vehicle Doors All fully open
        Compressor speed 5200 rpm
        Temperature Setting MAX COLD
        Blower Speed HI
        A/C switch ON
        R/F Switch

        RECIRCULATION

        (30 to 35°C (86 to 95°F))

        Standard Pressure
        Low pressure side
        0.15 to 0.25 MPa (1.5 to 2.5 kgf/cm2, 21.3 to 35.6 psi)
        High pressure side
        1.37 to 1.57 MPa (14 to 16 kgf/cm2, 199 to 228 psi)

    NG
    OK