DATA LIST
Tech Tips
Using the intelligent tester to read the Data List allows the values or states of switches, sensors, actuators and other items to be read without removing any parts. This non-intrusive inspection can be very useful because intermittent conditions or signals may be discovered before parts or wiring is disturbed. Reading the Data List information early in troubleshooting is one way to save diagnostic time.
Note
In the table below, the values listed under "Normal Condition" are reference values. Do not depend solely on these reference values when deciding whether a part is faulty or not.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Data List.
Check the value(s) by referring to the table below.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Room Temperature Sensor | Room temperature sensor / Min.: -6.5°C (20.3°F) Max.: 57.25°C (135.05°F) |
Actual cabin temperature displayed | - |
| Ambient Temp Sensor | Ambient temperature sensor / Min.: -23.3°C (-9.94°F) Max.: 65.95°C (150.71°F) |
Actual ambient temperature displayed | - |
| Adjusted Ambient Temp | Adjusted ambient temperature / Min.: -30.8°C (-23.44°F) Max.: 50.8°C (123.44°F) |
- | - |
| Evaporator Temp Sensor | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Fin Thermistor | Evaporator temperature sensor / Min.: -29.7°C (-21.46°F) Max.: 59.55°C (139.19°F) |
Actual evaporator temperature displayed | - |
| Evaporator Target Temp | Evaporator target temperature / Min.: -327.68°C (-557.82°F) Max.: 327.67°C (621.81°F) |
Evaporator target temperature displayed | - |
| Solar Sensor (D side) | Driver side solar sensor / Min.: 0 Max.: 255 |
Driver side solar sensor value increases as brightness increases | - |
| Solar Sensor (P side) | Passenger side solar sensor / Min.: 0 Max.: 255 |
Passenger side solar sensor value increases as brightness increases | - |
| Engine Coolant Temp | Engine coolant temperature sensor / Min.: 1.3°C (34.34°F) Max.: 90.55°C (194.99°F) |
Actual engine coolant temperature displayed | - |
| Set Temperature (D side) | Driver side set temperature / for Europe: Min.: 16°C (65°F) Max.: 30°C (85°F) except Europe: Min.: 18°C (65°F) Max.: 32°C (85°F) |
Driver side actual set temperature displayed | - |
| Set Temperature (P side) | Passenger side set temperature / for Europe: Min.: 16°C (65°F) Max.: 30°C (85°F) except Europe: Min.: 18°C (65°F) Max.: 32°C (85°F) |
Passenger side actual set temperature displayed | - |
| Blower Motor Speed Level | Blower motor speed level / Min.: 0 Max.: 31 |
Displayed speed level increases in range between 0 and 31 as blower motor speed increases | - |
| Emission Gas Nox Sensor*1 | Emission gas / Min.: 0 Max.: 255 |
Smog ventilation sensor value increases as gas amount increases | - |
| Emission Gas Sensor*1 | Emission gas / Min.: 0 Max.: 255 |
Smog ventilation sensor value increases as gas amount increases | - |
| Regulator Pressure Sensor | Air conditioning pressure sensor / Min.: -0.45668 MPaG Max.: 3.29437 MPaG |
Actual regulator pressure displayed | - |
| Humidity Sensor | Humidity sensor / Min.: 0% Max.: 100% |
Actual cabin humidity displayed | - |
| Air Mix Servo Targ Pulse (D) | Driver side air mix servo motor target pulse / Min.: 0 Max.: 255 |
for LHD: MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) for RHD: MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) |
- |
| Air Mix Servo Actual Pulse (D) | Driver side air mix servo motor actual pulse / Min.: 0 Max.: 255 |
for LHD: MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) for RHD: MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) |
- |
| Air Mix Servo Targ Pulse (P) | Passenger side air mix servo motor target pulse / Min.: 0 Max.: 255 |
for LHD: MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) for RHD: MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) |
- |
| Air Mix Servo Actual Pulse (P) | Passenger side air mix servo motor actual pulse / Min.: 0 Max.: 255 |
for LHD: MAX. COLD: 5 (pulse) MAX. HOT: 103 (pulse) for RHD: MAX. COLD: 105 (pulse) MAX. HOT: 7 (pulse) |
- |
| Air Outlet Servo Pulse (D) | Air outlet servo motor target pulse / Min.: 0 Max.: 255 |
FACE: 8 (pulse) B/L: 30 to 38 (pulse) FOOT: 50 to 74 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) |
- |
| Air Outlet Servo Actu Pulse (D) | Air outlet servo motor actual pulse / Min.: 0 Max.: 255 |
FACE: 8 (pulse) B/L: 30 to 38 (pulse) FOOT: 50 to 74 (pulse) FOOT/DEF: 80 (pulse) DEF: 97 (pulse) |
- |
| Air Inlet Damper Targ Pulse | Air inlet servo motor target pulse / Min.: 0 Max.: 255 |
RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) |
- |
| Air Inlet Damper Actual Pulse | Air inlet servo motor actual pulse / Min.: 0 Max.: 255 |
RECIRCULATION: 7 (pulse) FRESH: 28 (pulse) |
- |
| Compressor Speed | Compressor speed / Min.: 0 rpm Max.: 65535 rpm |
Actual rotation speed in the range between 0 rpm and 7500 rpm displayed | - |
| Compressor Target Speed | Compressor target speed / Min.: 0 rpm Max.: 65535 rpm |
Actual rotation speed in the range between 0 rpm and 7500 rpm displayed | - |
| Number of Trouble Codes | Number of trouble codes / Min.: 0 Max.: 255 |
Number of DTCs displayed | - |
*1: w/ Navigation System
ACTIVE TEST
Tech Tips
Using the intelligent tester to perform Active Tests allows relays, VSVs, actuators and other items to be operated without removing any parts. This non-intrusive functional inspection can be very useful because intermittent operation may be discovered before parts or wiring is disturbed. Performing Active Tests early in troubleshooting is one way to save diagnostic time. Data List information can be displayed while performing Active Tests.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Body / Air Conditioner / Active Test.
Check the operation by referring to the table below.
| Tester Display | Test Part | Control Range | Diagnostic Note |
|---|---|---|---|
| Blower Motor | Blower motor | Min.: 0, Max.: 31 | - |
| Compressor Target Speed | Compressor target speed | Min.: 0, Max.: 7500 | - |
| Magnetic Clutch Relay | A/C compressor | OFF, ON | - |
| Defogger Relay (Rear) | Defogger relay (Rear) | OFF, ON | - |
| Deicer Relay (Front) | Deicer relay (Front) | OFF, ON | - |
| Water Pump | Water pump relay | OFF, ON | - |
| Air Mix Servo Targ Pulse (D) | Air mix servo motor pulse (D side) | Min.: 0, Max.: 255 | - |
| Air Mix Servo Targ Pulse (P) | Air mix servo motor pulse (P side) | Min.: 0, Max.: 255 | - |
| Air Outlet Servo Pulse (D) | Air outlet servo motor pulse | Min.: 0, Max.: 255 | - |
| Air Inlet Damper Targ Pulse | Air inlet damper target pulse | Min.: 0, Max.: 255 | - |