FREEZE FRAME DATA/INFORMATION
Whenever an ABS, VSC, electronically controlled brake system DTC is detected, the skid control ECU stores the current vehicle (sensor) state as Freeze Frame Data.
The skid control ECU stores the number of times (maximum: 31) the power switch has been turned from off to on (IG) since the last time the ABS was activated.
For DTCs stored in the skid control ECU, information (INF) codes that are contained in the Freeze Frame Data can be displayed on the intelligent tester.
Tech Tips
However, if the vehicle is stopped or at a low speed (7 km/h (4.3 mph) or less), or if a DTC is detected, the skid control ECU will stop counting the number of times the power switch had been turned from off to on (IG).
Freeze Frame Data at the time the ABS operates:
The skid control ECU stores and updates data whenever the ABS system operates.
When the ECU stores data at the time a DTC is detected, the data stored during ABS operation is cleared.
Freeze Frame Data at the time a DTC is detected:
When the skid control ECU stores data at the time a DTC is detected, no updates will be performed until the data is cleared.
CHECK FREEZE FRAME DATA AND INFORMATION
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Enter the following menus: Chassis / ABS/VSC/TRC / DTC.
According to the display on the intelligent tester, select the DTC data display with Freeze Frame Data.
Read the Freeze Frame Data recorded when the DTC was set.
Read the information.
Select the item that has an information (INF) code from the Freeze Frame Data screen.
| Tester Display | Measurement Item/Range | Normal Condition | Diagnostic Note |
|---|---|---|---|
| Detailed Freeze DTC | Detailed code for Freeze Frame DTC / Min.: 0, Max.: 65535 | - | Number of information (INF) code output is displayed |
| Elapsed Time after Freeze Trigger | Elapsed time after freeze trigger / Min.: 0 msec, Max.: 500 msec | - | - |
| Number of IG ON | Number of operations of power switch on (IG) after storing Freeze Frame Data / 0 to 31 | - | - |
| Elapsed Time | Elapsed time after power switch on (IG) / Min.: 0 sec., Max.: 100661.76 sec. | - | - |
| Buzzer | Skid control buzzer / ON or OFF | ON: Buzzer on OFF: Buzzer off |
- |
| Stop Light SW | Stop light switch / ON or OFF | ON: Brake pedal depressed OFF: Brake pedal released |
- |
| Parking Brake SW | Parking brake switch / ON or OFF | ON: Parking brake applied OFF: Parking brake released |
- |
| TRC(TRAC)/VSC OFF SW | VSC OFF switch / ON or OFF | ON: Switch on OFF: Switch off |
- |
| Reservoir Warning SW | Brake fluid level warning switch / ON or OFF | ON: Reservoir level low OFF: Reservoir level normal |
- |
| Shift Lever Position | Shift lever position information / Fail, 1st-6th/B, D/M, P/N or R | Actual shift lever position | - |
| Operated System | Operated system status / ABS, VSC, TRAC, BA, PB, PBA, HAB, HA-CTRL, Fail, Non or Sys | - | ABS: ABS activated VSC: VSC activated TRAC: TRC activated BA: BA activated PB: PB activated PBA: PBA activated HAB: HAB activated HA-CTRL: Hill-start assist control activated Fail: Fail safe mode activated Non: No system activated Sys: System prohibited |
| Master Cylinder Sensor | Master cylinder pressure sensor 1 / Min.: 0 V, Max.: 5 V | When brake pedal released: 0.3 to 0.7 V | Reading increases when brake pedal is depressed |
| M/C Sensor Grade | Master cylinder pressure sensor change / Min.: -30 MPa/s, Max.: 225 MPa/s | When brake pedal is released or pedal held at constant position: 0 MPa/s | When brake pedal is being depressed: Changes in proportion with pedal movement speed |
| Master Cylinder Sensor2 | Master cylinder pressure sensor 2 / Min.: 0 V, Max.: 5 V | When brake pedal released: 0.3 to 0.7 V | Reading increases when brake pedal is depressed |
| Stroke Sensor | Brake pedal stroke sensor / Min.: 0 V, Max.: 5 V | When brake pedal released: 0.8 to 1.2 V | Reading increases when brake pedal is depressed |
| Stroke Sensor2 | Brake pedal stroke sensor 2 / Min.: 0 V, Max.: 5 V | When brake pedal released: 3.8 to 4.2 V | Reading increases when brake pedal is depressed |
| Accumulator Sensor | Accumulator pressure sensor / Min.: 0 V, Max.: 5 V | Specified value: 2.6 to 3.8 V | When brake fluid is stored in the accumulator: Accumulator pressure changes in accordance with volume of fluid stored in the accumulator |
| Yaw Rate Sensor | Yaw rate sensor / Min.: -128 °/s, Max.: 127 °/s | Vehicle stopped: 0 °/s Turning right: -128 to 0 °/s Turning left: 0 to 127 °/s |
- |
| FR W/C Sensor | FR wheel cylinder pressure sensor / Min.: 0 V, Max.: 5 V | When brake pedal released: 0.3 to 0.7 V | Reading increases when brake pedal is depressed |
| FL W/C Sensor | FL wheel cylinder pressure sensor / Min.: 0 V, Max.: 5 V | When brake pedal released: 0.3 to 0.7 V | Reading increases when brake pedal is depressed |
| RR W/C Sensor | RR wheel cylinder pressure sensor / Min.: 0 V, Max.: 5 V | When brake pedal released: 0.3 to 0.7 V | Reading increases when brake pedal is depressed |
| RL W/C Sensor | RL wheel cylinder pressure sensor / Min.: 0 V, Max.: 5 V | When brake pedal released: 0.3 to 0.7 V | Reading increases when brake pedal is depressed |
| Lateral G | Lateral G / Min.: -25.20 m/s2, Max.: 24.91 m/s2 |
- | During turning: Changes in proportion with acceleration |
| Forward and Rearward G | Forward and backward G / Min.: -25.11 m/s2, Max.: 24.91 m/s2 |
- | During acceleration/deceleration: Changes in proportion with acceleration |
| FR Wheel Speed | FR wheel speed sensor / Min.: 0 km/h (0 mph), Max.: 326.4 km/h (202 mph) | Vehicle stopped: 0 km/h (0 mph) | When driving at constant speed: No large fluctuations |
| FL Wheel Speed | FL wheel speed sensor / Min.: 0 km/h (0 mph), Max.: 326.4 km/h (202 mph) | Vehicle stopped: 0 km/h (0 mph) | When driving at constant speed: No large fluctuations |
| RR Wheel Speed | RR wheel speed sensor / Min.: 0 km/h (0 mph), Max.: 326.4 km/h (202 mph) | Vehicle stopped: 0 km/h (0 mph) | When driving at constant speed: No large fluctuations |
| RL Wheel Speed | RL wheel speed sensor / Min.: 0 km/h (0 mph), Max.: 326.4 km/h (202 mph) | Vehicle stopped: 0 km/h (0 mph) | When driving at constant speed: No large fluctuations |
| Vehicle Speed | Maximum wheel speed sensor / Min.: 0 km/h (0 mph), Max.: 326.4 km/h (202 mph) | Vehicle stopped: 0 km/h (0 mph) | When driving at constant speed: No large fluctuations |
| Accelerator Opening Angle % | The difference of a present accelerator / Min.: 0%, Max.: 127% | When the accelerator pedal released: 0% | During accelerator pedal operation: Changes in proportion with the pedal movement |
| ECB* Motor Relay | ABS motor relay / ON or OFF | ON: Relay on OFF: Relay off |
- |
| ECB* Motor Relay2 | ABS motor relay 2 / ON or OFF | ON: Relay on OFF: Relay off |
- |
| ECB* Main Relay | ABS main relay / ON or OFF | ON: Relay on OFF: Relay off |
- |
| ECB* Main Relay2 | ABS main relay 2 / ON or OFF | ON: Relay on OFF: Relay off |
- |
| ECB* Solenoid (SMC1) | Master cut solenoid (SMC1) / ON or OFF | ON: Solenoid on OFF: Solenoid off |
- |
| ECB* Solenoid (SMC2) | Master cut solenoid (SMC2) / ON or OFF | ON: Solenoid on OFF: Solenoid off |
- |
| ECB* Solenoid (SCSS) | Stroke simulator solenoid (SCSS) / ON or OFF | ON: Solenoid on OFF: Solenoid off |
- |
| Capacitor Mode | Capacitor mode/ ON or OFF | ON: Mode on OFF: Mode off |
- |
| IG1 Voltage Value | IG1 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| IG2 Voltage Value | IG2 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| BS1 Voltage Value | BS1 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| BS2 Voltage Value | BS2 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| VM1 Voltage Value | VM1 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| VM2 Voltage Value | VM2 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| +B1 Voltage Value | +B1 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| +B2 Voltage Value | +B2 voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| Motor Relay Voltage Value | Motor relay voltage value / Min.: 0 V, Max.: 20 V | - | Changes in proportion to auxiliary battery voltage |
| SLAFR Solenoid Current | Linear solenoid (FRA) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| SLAFL Solenoid Current | Linear solenoid (FLA) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| SLARR Solenoid Current | Linear solenoid (RRA) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| SLARL Solenoid Current | Linear solenoid (RLA) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| SLRFR Solenoid Current | Linear solenoid (FRR) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| SLRFL Solenoid Current | Linear solenoid (FLR) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| SLRRR Solenoid Current | Linear solenoid (RRR) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| SLRRL Solenoid Current | Linear solenoid (RLR) current / Min.: 0 A, Max.: 1.5 A | When brake pedal released: 0 A | - |
| FR Target Oil Pressure | FR wheel target hydraulic pressure / Min.: 0 MPa, Max.: 20 MPa | Changes according to the target wheel cylinder hydraulic pressure | - |
| FL Target Oil Pressure | FL wheel target hydraulic pressure / Min.: 0 MPa, Max.: 20 MPa | Changes according to the target wheel cylinder hydraulic pressure | - |
| RR Target Oil Pressure | RR wheel target hydraulic pressure / Min.: 0 MPa, Max.: 20 MPa | Changes according to the target wheel cylinder hydraulic pressure | - |
| RL Target Oil Pressure | RL wheel target hydraulic pressure / Min.: 0 MPa, Max.: 20 MPa | Changes according to the target wheel cylinder hydraulic pressure | - |
| Inspection Mode | Inspection mode / Other or Inspect | Other: Normal mode Inspect: Inspection mode |
- |
| Steering Angle Sensor | Steering angle sensor / Min.: - 3276.8 °, Max.: 3276.7 ° | Left turn: Increase Right turn: Decrease |
- |
| VCM1 Voltage Value | VCM voltage value / Min.: 0 V, Max.: 10 V | Specified value: 4.8 to 5.2 V | - |
| VCM2 Voltage Value | VCM2 voltage value / Min.: 0 V, Max.: 10 V | Specified value: 4.8 to 5.2 V | - |
| TRC/VSC Off Mode | TRC/VSC off mode / Normal, TRC OFF or VSC OFF | Normal: Normal mode TRC OFF: TRC off mode VSC OFF: VSC off mode |
- |
*: Electronically Controlled Brake System
CLEAR FREEZE FRAME DATA AND INFORMATION
Note
Clearing the DTCs will also clear the Freeze Frame Data and information (INF) codes.
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Turn the intelligent tester on.
Clear the DTCs and Freeze Frame Data Click here.