PNEUMATIC TANK INSPECTION


  1. INSPECT PNEUMATIC TANK WITH TUBE ASSEMBLY (LOW PRESSURE TANK VALVE)


    1. A01NHQXE04
      Text in Illustration
      *1 Component without harness connected (Low pressure tank valve)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      2 (B) - 1 (L) 15 to 25°C (59 to 77°F) 10 to 14 Ω
    2. Check the low pressure tank valve operation.


      1. Connect a positive (+) lead from the battery to terminal 2 (B), and a negative (-) lead to terminal 1 (L).

      2. Check the operating sound of the low pressure tank valve.

        OK
        It makes an operating sound.

        If the value is not as specified replace the pneumatic tank with tube assembly.