INSPECT HEIGHT CONTROL COMPRESSOR (EXHAUST VALVE)
| *1 | Component without harness connected (Exhaust valve) |
Measure the resistance of the exhaust valve.
Measure the resistance according to the value(s) in the table below.
| Standard Resistance | ||||||
|---|---|---|---|---|---|---|
|
| *1 | Component without harness connected (Exhaust valve) |
Check the exhaust valve operation.
Connect a positive (+) lead from the battery to terminal 2 (B), and a negative (-) lead to terminal 1 (L).
Check the operating sound of the height control valve.
| OK |
|---|
| It makes an operating sound. |
If the value is not as specified, replace the height control compressor.
INSPECT HEIGHT CONTROL COMPRESSOR (COMPRESSOR MOTOR)
Check the compressor operation.
| *1 | Component without harness connected (Compressor motor) |
Connect a positive (+) lead from the battery to terminal 1 (B) and a negative (-) lead to terminal 2 (E).
Check the operation of the compressor motor.
| OK |
|---|
| Motor operates. |
If the value is not as specified, replace the height control compressor.
Note
Do not operate the height control compressor for 60 seconds or more.
Stop applying voltage immediately if the compressor stops operating because a short will occur and the compressor motor will lock up, causing the flow of excessive current.