SHIFT LEVER POSITION SENSOR INSPECTION


  1. INSPECT SHIFT LEVER POSITION SENSOR


    1. A01NFN6E06
      Text in Illustration
      *1

      Component without harness connected

      (Shift Lever Position Sensor)

      Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Shift Lever Position 8 (+B) - 1(D) 8 (+B) - 2 (N) 8 (+B) - 3 (P) 8 (+B) - 4 (R) 8 (+B) - 5 (MJ) 8 (+B) - 6 (FD) 8 (+B) - 7 (B) 8 (+B) - 9 (RV)
      P 10 kΩ or higher 4.2 to 5.2 kΩ or higher Below 1 Ω 10 kΩ or higher Below 1 Ω 10 kΩ or higher 10 kΩ or higher 10 kΩ or higher
      R 10 kΩ or higher 4.2 to 5.2 kΩ or higher 10 kΩ or higher Below 1 Ω Below 1 Ω 10 kΩ or higher 10 kΩ or higher Below 1 Ω
      N 10 kΩ or higher Below 1 Ω 10 kΩ or higher 10 kΩ or higher Below 1 Ω 10 kΩ or higher 10 kΩ or higher 10 kΩ or higher
      D Below 1 Ω 4.2 to 5.2 kΩ or higher 10 kΩ or higher 10 kΩ or higher Below 1 Ω Below 1 Ω 10 kΩ or higher 10 kΩ or higher
      B 10 kΩ or higher 4.2 to 5.2 kΩ or higher 10 kΩ or higher 10 kΩ or higher Below 1 Ω Below 1 Ω Below 1 Ω 10 kΩ or higher

      If the result is not as specified, replace the shift lever position sensor.