| DTC Code | DTC Name |
|---|---|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit |
| P0AC1-123 | Hybrid Battery Pack Current Sensor "A" Circuit Low |
| P0AC2-123 | Hybrid Battery Pack Current Sensor "A" Circuit High |
DESCRIPTION
The battery current sensor, which is mounted on the positive cable side of the HV battery assembly, detects the amperage that flows into the HV battery. The battery smart unit inputs a voltage, which varies between 0 and 5 V in proportion to the amperage, into the IB terminal from the battery current sensor. An output voltage of the battery current sensor below 2.5 V indicates that the HV battery is being discharged, and above 2.5 V indicates that the HV battery is being charged. The power management control ECU determines the charging and discharging amperage of the HV battery based on the signals that are input to its IB terminal from the battery smart unit, and calculates the SOC (state of charge) of the HV battery through the accumulated amperage.
| DTC No. | DTC Detection Condition | Trouble Area |
|---|---|---|
| P0ABF-123 P0AC1-123 P0AC2-123 |
When the battery current sensor is abnormal (1 trip detection) |
|
WIRING DIAGRAM
INSPECTION PROCEDURE
CAUTION:
Before inspecting the high-voltage system, take safety precautions to prevent electrical shocks, such as wearing insulated gloves and removing the service plug grip. After removing the service plug grip, put it in your pocket to prevent other technicians from accidentally reconnecting it while you are working on the high-voltage system.
After disconnecting the service plug grip, wait for at least 10 minutes before touching any of the high-voltage connectors or terminals.
Tech Tips
At least 10 minutes is required to discharge the high-voltage capacitor inside the inverter with converter assembly.
Note
After the power switch is turned off, the display and navigation module display (HDD navigation system) records various types of memory and settings. As a result, after turning the power switch off, make sure to wait for the time specified in the following table before disconnecting the cable from the negative (-) battery terminal.
| Specification | Waiting Time |
|---|---|
| w/o Telematics transceiver | 60 sec. |
| w/ Telematics transceiver | 120 sec. |
PROCEDURE
CHECK DTC OUTPUT (DTC P0AFC-123 IS OUTPUT)
Connect the intelligent tester to the DLC3.
Turn the power switch on (IG).
Enter the following menus: Powertrain / Hybrid Control / Trouble Codes.
Read output DTCs Click here.
| Result | ||||||
|---|---|---|---|---|---|---|
|
Disconnect the intelligent tester from the DLC3.
| B |
|
GO TO DTC CHART |
| A |
|
CHECK HARNESS AND CONNECTOR (HYBRID BATTERY JUNCTION BLOCK ASSEMBLY - BATTERY SMART UNIT)
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the battery cover Click here.
Remove the battery smart unit.
Tech Tips
Disconnect only the z29 connector of the battery smart unit.
Disconnect the z33 battery current sensor connector from the hybrid battery junction block assembly .
| *1 | Rear view of wire harness connector (to Battery Smart Unit) |
| *2 | Front view of wire harness connector (to Hybrid Battery Junction Block Assembly) |
Measure the resistance according to the value(s) in the table below.
| Standard Resistance (Check for Open) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
| Standard Resistance (Check for Short) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Connect the z33 battery current sensor connector to the hybrid battery junction block assembly.
Install the battery smart unit Click here.
Install the battery cover.
Connect the cable to the negative (-) battery terminal.
| NG |
|
REPAIR OR REPLACE HARNESS OR CONNECTOR |
| OK |
|
CHECK BATTERY SMART UNIT (VIB VOLTAGE)
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the battery cover Click here.
Remove the battery smart unit
Tech Tips
Do not disconnect the battery smart unit connector.
Connect the cable to the negative (-) battery terminal.
Turn the power switch on (IG).
| *1 | Component with harness connected (Battery Smart Unit) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
Turning the power switch on (IG) with the service plug grip removed causes an interlock switch system DTC (P0A0D-350) to be set. Use the intelligent tester to clear the DTCs Click here.
Turn the power switch off.
Disconnect the cable from the negative (-) battery terminal.
Install the battery smart unit Click here.
Install the battery cover.
Connect the cable to the negative (-) battery terminal.
| NG |
|
REPLACE BATTERY SMART UNIT Click here |
| OK |
|
CHECK BATTERY SMART UNIT
CAUTION:
Be sure to wear insulated gloves and protective goggles.
Disconnect the cable from the negative (-) battery terminal.
Check that the service plug grip is not installed.
Note
After removing the service plug grip, do not turn the power switch on (READY), unless instructed by the repair manual because this may cause a malfunction.
Remove the battery cover Click here.
Remove the battery smart unit
Tech Tips
Do not disconnect the battery smart unit connector.
Connect the cable to the negative (-) battery terminal.
Turn the power switch on (IG).
| *1 | Component with harness connected (Battery Smart Unit) |
Measure the voltage according to the value(s) in the table below.
| Standard Voltage | ||||||
|---|---|---|---|---|---|---|
|
Tech Tips
Turning the power switch on (IG) with the service plug grip removed causes an interlock switch system DTC (P0A0D-350) to be set. Use the intelligent tester to clear the DTCs Click here.
Turn the power switch off.
Disconnect the cable from the negative (-) battery terminal.
Install the battery smart unit Click here.
Install the battery cover.
Connect the cable to the negative (-) battery terminal.
| NG |
|
REPLACE HYBRID BATTERY JUNCTION BLOCK ASSEMBLY Click here |
| OK |
|
REPLACE BATTERY SMART UNIT Click here