AUDIO AND VISUAL SYSTEM (w/ Navigation System) Vehicle Speed Signal Circuit between Stereo Component Amplifier and Combination Meter

DESCRIPTION

The circuit is necessary for the Automatic Sound Levelizer (ASL) built into the stereo component amplifier assembly.

Speed signals are received from the combination meter assembly and used for the ASL.

The ASL function automatically adjusts the sound volume in order to clear audio quality even when vehicle noise increases (as vehicle noise increases, the volume is turned up etc.).

Tech Tips


  • A voltage of 12 V or 5 V is output from each ECU and then input to the combination meter assembly. The signal is changed to a pulse signal at the transistor in the combination meter assembly. Each ECU controls the respective system based on the pulse signal.

  • If a short occurs in any of the ECUs or in the wire harness connected to an ECU, all systems in the diagram below will not operate normally.

WIRING DIAGRAM

A01NEKPE01

INSPECTION PROCEDURE

PROCEDURE


  1. INSPECT COMBINATION METER ASSEMBLY (OUTPUT WAVEFORM)


    1. A01NCPVE19
      Text in Illustration
      *1

      Component with harness connected

      (Combination Meter Assembly)

      Check the output waveform.


      1. Remove the combination meter assembly with the connector(s) still connected.

      2. Connect an oscilloscope to terminal F15-3 (+S) and body ground.

      3. Turn the power switch on (IG).

      4. Turn a wheel slowly.

      5. Check the signal waveform according to the condition(s) in the table below.

        Item Condition
        Measurement terminal F15-3 (+S) - Body ground
        Tool setting 5 V/DIV., 20 ms./DIV.
        Vehicle condition Wheel being rotated
        OK
        The waveform is similar to that shown in the illustration.

        Tech Tips

        When the system is functioning normally, one wheel revolution generates 4 pulses. As the vehicle speed increases, the width indicated by (A) in the illustration narrows.


    NG
    OK
  2. CHECK HARNESS AND CONNECTOR


    1. A01NF1VE01
      Text in Illustration
      *1

      Front view of wire harness connector

      (to Stereo Component Amplifier Assembly)

      *2

      Front view of wire harness connector

      (to Combination Meter Assembly)

      Disconnect the stereo component amplifier assembly connector and combination meter assembly connector.

    2. Measure the resistance according to the value(s) in the table below.

      Standard Resistance
      Tester Connection Condition Specified Condition
      O15-2 (SPD) - F15-3 (+S) Always Below 1 Ω

    NG
    OK