| DTC Code | Detection Item | Trouble Area | MIL | See page |
|---|---|---|---|---|
| P0A7F-123 | Hybrid Battery Pack Deterioration | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P0A80-123 | Replace Hybrid Battery Pack | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P0A82-123 | Hybrid Battery Pack Cooling Fan 1 | 1. Power management control ECU 2. Battery smart unit 3. Battery cooling blower assembly (No. 0) 4. Wire harness or connector |
- | |
| P0A84-123 | Hybrid Battery Pack Cooling Fan 1 | 1. BATT FAN relay 2. BATT FAN fuse 3. Battery cooling blower assembly (No. 0) 4. Battery cooling blower assembly (No. 1) 5. Battery cooling blower assembly (No. 2) 6. Battery smart unit 7. Power management control ECU 8. Wire harness or connector 9. Engine room relay block No. 3 |
- | |
| P0A85-123 | Hybrid Battery Pack Cooling Fan 1 Control Circuit High | 1. HV battery assembly 2. Battery cooling blower assembly (No. 0) 3. Battery smart unit 4. Hybrid battery junction block assembly 5. Wire harness or connector |
- | |
| P0A95-123 | High Voltage Fuse | 1. Electric vehicle battery plug assembly 2. No. 2 HV battery pack cable 3. Service plug grip 4. HV battery assembly |
- | |
| P0A97-123 | Hybrid Battery Pack Cooling Fan 2 Performance / Stuck OFF | 1. Power management control ECU 2. Battery smart unit 3. Battery cooling blower assembly (No. 1) 4. Wire harness or connector |
- | |
| P0A99-123 | Hybrid Battery Pack Cooling Fan 2 Control Circuit Low | 1. BATT FAN relay 2. BATT FAN fuse 3. Battery cooling blower assembly (No. 0) 4. Battery cooling blower assembly (No. 1) 5. Battery cooling blower assembly (No. 2) 6. Battery smart unit 7. Power management control ECU 8. Wire harness or connector 9. Engine room relay block No. 3 |
- | |
| P0A9A-123 | Hybrid Battery Pack Cooling Fan 2 Control Circuit High | 1. HV battery assembly 2. Battery cooling blower assembly (No. 1) 3. Battery smart unit 4. Hybrid battery junction block assembly 5. Wire harness or connector |
- | |
| P0A9C-123 | Hybrid Battery Temperature Sensor "A" Range / Performance | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0A9D-123 | Hybrid Battery Temperature Sensor "A" Circuit Low | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0A9E-123 | Hybrid Battery Temperature Sensor "A" Circuit High | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0ABF-123 | Hybrid Battery Pack Current Sensor Circuit | 1. Hybrid battery junction block assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0AC0-123 | Hybrid Battery Pack Current Sensor Circuit Range / Performance | 1. Hybrid battery junction block assembly 2. Battery smart unit |
Comes on |
|
| P0AC1-123 | Hybrid Battery Pack Current Sensor "A" Circuit Low | 1. Hybrid battery junction block assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0AC2-123 | Hybrid Battery Pack Current Sensor "A" Circuit High | 1. Hybrid battery junction block assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0AC6-123 | Hybrid Battery Temperature Sensor "B" Range / Performance | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0AC7-123 | Hybrid Battery Temperature Sensor "B" Circuit Low | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0AC8-123 | Hybrid Battery Temperature Sensor "B" Circuit High | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0ACB-123 | Hybrid Battery Temperature Sensor "C" Range / Performance | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0ACC-123 | Hybrid Battery Temperature Sensor "C" Circuit Low | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0ACD-123 | Hybrid Battery Temperature Sensor "C" Circuit High | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0AD0-123 | Hybrid Battery Pack Cooling Fan 3 Performance / Stuck OFF | 1. Power management control ECU 2. Battery smart unit 3. Battery cooling blower assembly (No. 2) 4. Wire harness or connector |
- | |
| P0AD2-123 | Hybrid Battery Pack Cooling Fan 3 Control Circuit Low | 1. BATT FAN relay 2. BATT FAN fuse 3. Battery cooling blower assembly (No. 0) 4. Battery cooling blower assembly (No. 1) 5. Battery cooling blower assembly (No. 2) 6. Battery smart unit 7. Power management control ECU 8. Wire harness or connector 9. Engine room relay block No. 3 |
- | |
| P0AD3-123 | Hybrid Battery Pack Cooling Fan 3 Control Circuit High | 1. HV battery assembly 2. Battery cooling blower assembly (No. 2) 3. Battery smart unit 4. Hybrid battery junction block assembly 5. Wire harness or connector |
- | |
| P0AE9-123 | Hybrid Battery Temperature Sensor "D" Range / Performance | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0AEA-123 | Hybrid Battery Temperature Sensor "D" Circuit Low | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0AEB-123 | Hybrid Battery Temperature Sensor "D" Circuit High | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0AFC-123 | Hybrid Battery Pack Sensor Module | 1. Battery smart unit 2. Wire harness or connector 3. IGCT No. 3 fuse 4. IGCT MAIN relay |
Comes on |
|
| P0B3D-123 | Hybrid Battery Voltage Sensor "A" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B42-123 | Hybrid Battery Voltage Sensor "B" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B47-123 | Hybrid Battery Voltage Sensor "C" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B4C-123 | Hybrid Battery Voltage Sensor "D" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B51-123 | Hybrid Battery Voltage Sensor "E" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B56-123 | Hybrid Battery Voltage Sensor "F" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B5B-123 | Hybrid Battery Voltage Sensor "G" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B60-123 | Hybrid Battery Voltage Sensor "H" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B65-123 | Hybrid Battery Voltage Sensor "I" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B6A-123 | Hybrid Battery Voltage Sensor "J" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B6F-123 | Hybrid Battery Voltage Sensor "K" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B74-123 | Hybrid Battery Voltage Sensor "L" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B79-123 | Hybrid Battery Voltage Sensor "M" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B7E-123 | Hybrid Battery Voltage Sensor "N" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B83-123 | Hybrid Battery Voltage Sensor "O" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0B88-123 | Hybrid Battery Voltage Sensor "P" Circuit Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| P0BC3-123 | Hybrid Battery Temperature Sensor "E" Range / Performance | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0BC4-123 | Hybrid Battery Temperature Sensor "E" Circuit Low | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0BC5-123 | Hybrid Battery Temperature Sensor "E" Circuit High | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0C34-123 | Hybrid Battery Temperature Sensor "F" Range / Performance | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0C35-123 | Hybrid Battery Temperature Sensor "F" Circuit Low | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0C36-123 | Hybrid Battery Temperature Sensor "F" Circuit High | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector 4. Hybrid battery junction block assembly |
Comes on |
|
| P0C6E-123 | Hybrid Battery Temperature Sensor "A" / "B" Correlation | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0C70-123 | Hybrid Battery Temperature Sensor "C" / "D" Correlation | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P0C72-123 | Hybrid Battery Temperature Sensor "E" / "F" Correlation | 1. HV battery assembly 2. Battery smart unit 3. Wire harness or connector |
Comes on |
|
| P3011-123 | Battery Block 1 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3012-123 | Battery Block 2 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3013-123 | Battery Block 3 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3014-123 | Battery Block 4 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3015-123 | Battery Block 5 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3016-123 | Battery Block 6 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3017-123 | Battery Block 7 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3018-123 | Battery Block 8 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3019-123 | Battery Block 9 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3020-123 | Battery Block 10 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3021-123 | Battery Block 11 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3022-123 | Battery Block 12 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3023-123 | Battery Block 13 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3024-123 | Battery Block 14 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P3025-123 | Battery Block 15 Becomes Weak | 1. HV battery assembly 2. Battery smart unit |
Comes on |
|
| P308A-123 | Hybrid Battery Voltage Sensor All Circuits Low | 1. Battery smart unit 2. HV battery assembly |
Comes on |
|
| U029A-123 | Lost Communication with Hybrid Battery Pack Sensor Module | 1. Wire harness or connector 2. Power management control ECU 3. Battery smart unit |
Comes on |